beautypg.com
Manuals
Brands
Daikin Manuals
Heat Pump
Altherma EVLQ05+08CA
Daikin Altherma EVLQ05+08CA Manuals
Manuals and User Guides for Daikin Altherma EVLQ05+08CA. We have
2
Daikin Altherma EVLQ05+08CA manuals available for free PDF download: Installer's Reference Manual
Daikin Altherma EVLQ05+08CA Installer's Reference Manual (264 pages)
Hybrid heat pump
Brand:
Daikin
| Category:
Heat Pump
| Size: 13.02 MB
Table of Contents
Table of Contents
2
About the Product
6
About this Document
8
Meaning of Warnings and Symbols
8
Installer Reference Guide at a Glance
10
General Safety Precautions
12
For the Installer
12
General
12
Installation Site
13
Refrigerant - in Case of R410A or R32
14
Water
16
Electrical
16
Gas
18
Gas Exhaust
19
Local Legislation
19
Specific Installer Safety Instructions
21
About the Box
28
Outdoor Unit
28
To Unpack the Outdoor Unit
28
To Remove the Accessories from the Outdoor Unit
29
Indoor Unit
30
To Unpack the Indoor Unit
30
To Remove the Accessories from the Indoor Unit
31
Gas Boiler
31
To Unpack the Gas Boiler
31
To Remove the Accessories from the Gas Boiler
32
About the Units and Options
34
Identification
34
Identification Label: Outdoor Unit
34
Identification Label: Indoor Unit
35
Identification Label: Gas Boiler
35
Combining Units and Options
37
Possible Options for the Outdoor Unit
37
Possible Options for the Indoor Unit
38
Possible Options for the Gas Boiler
41
Possible Combinations of Indoor Unit and Outdoor Unit
46
Possible Combinations of Indoor Unit and Domestic Hot Water Tank
47
Unit Installation
48
Preparing the Installation Site
48
Installation Site Requirements of the Outdoor Unit
49
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
50
Installation Site Requirements of the Indoor Unit
51
Opening and Closing the Units
52
About Opening the Units
52
To Open the Outdoor Unit
52
To Open the Switch Box Cover of the Indoor Unit
53
To Open the Gas Boiler
54
To Open the Switch Box Cover of the Gas Boiler
54
To Close the Outdoor Unit
55
To Close the Indoor Unit
55
To Close the Gas Boiler
55
To Install the Gas Boiler Cover Plate
56
Mounting the Outdoor Unit
56
About Mounting the Outdoor Unit
56
Precautions When Mounting the Outdoor Unit
57
To Provide the Installation Structure
57
To Install the Outdoor Unit
59
To Provide Drainage
60
To Prevent the Outdoor Unit from Falling over
61
Mounting the Indoor Unit
62
About Mounting the Indoor Unit
62
Precautions When Mounting the Indoor Unit
62
To Install the Indoor Unit
62
Mounting the Gas Boiler
63
To Install the Gas Boiler
63
To Install the Condensate Trap
65
Connecting the Boiler to the Flue Gas System
66
To Change the Gas Boiler to 80/125 Concentric Connection
67
To Change the 60/100 Concentric Connection to a Dual Pipe Connection
68
Calculate the Total Piping Length
69
Appliance Categories and Pipe Lengths
70
Applicable Materials
74
Flue Pipe Position
75
Insulation of the Gas Exhaust and Air Intake
76
Fitting a Horizontal Flue System
76
Fitting a Vertical Flue System
77
Plume Management Kit
77
Flues in Voids
78
Flue Gas Materials (C63) Available on the Market
79
About Securing the Flue System
80
Condensate Pipe Work
81
Internal Connections
82
External Connections
83
Piping Installation
84
Preparing Refrigerant Piping
84
Refrigerant Piping Requirements
84
Refrigerant Piping Insulation
85
Connecting the Refrigerant Piping
85
About Connecting the Refrigerant Piping
85
Precautions When Connecting the Refrigerant Piping
86
Guidelines When Connecting the Refrigerant Piping
87
Pipe Bending Guidelines
87
To Flare the Pipe End
87
To Braze the Pipe End
88
Using the Stop Valve and Service Port
89
To Connect the Refrigerant Piping to the Outdoor Unit
90
To Connect the Refrigerant Piping to the Indoor Unit
91
Checking the Refrigerant Piping
91
About Checking the Refrigerant Piping
91
Precautions When Checking the Refrigerant Piping
92
To Check for Leaks
92
To Perform Vacuum Drying
92
To Insulate the Refrigerant Piping
93
Charging Refrigerant
94
About Charging Refrigerant
94
Precautions When Charging Refrigerant
95
To Determine the Additional Refrigerant Amount
95
To Determine the Complete Recharge Amount
95
To Charge Additional Refrigerant
95
To Fix the Fluorinated Greenhouse Gases Label
96
Preparing Water Piping
96
Water Circuit Requirements
96
Formula to Calculate the Expansion Vessel Pre-Pressure
99
To Check the Water Volume and Flow Rate
100
Changing the Pre-Pressure of the Expansion Vessel
102
To Check the Water Volume: Examples
103
Connecting Water Piping
103
About Connecting the Water Piping
103
Precautions When Connecting the Water Piping
103
Connecting the Water Piping of the Indoor Unit
104
Connecting the Water Piping of the Gas Boiler
105
To Fill the Space Heating Circuit
106
To Fill the Domestic Water Circuit of the Gas Boiler
107
To Fill the Domestic Hot Water Tank
107
To Insulate the Water Piping
107
Connecting the Gas Piping
108
To Connect the Gas Pipe
108
To Perform an Air Purge on the Gas Supply
108
Electrical Installation
110
About Connecting the Electrical Wiring
110
Precautions When Connecting the Electrical Wiring
111
Guidelines When Connecting the Electrical Wiring
111
Overview of Electrical Connections Except External Actuators
113
Overview of Electrical Connections for External and Internal Actuators
114
About Preferential Kwh Rate Power Supply
115
Connections to the Outdoor Unit
116
To Connect the Electrical Wiring to the Outdoor Unit
116
Connections to the Indoor Unit
117
To Connect the Electrical Wiring to the Indoor Unit
117
To Connect the Main Power Supply of the Indoor Unit
118
To Connect the Main Power Supply of the Gas Boiler
120
To Connect the Communication Cable between Gas Boiler and Indoor Unit
120
To Connect the User Interface
122
To Connect the Shut-Off Valve
124
To Connect the Electrical Meter
125
To Connect the Gas Meter
125
To Connect the Domestic Hot Water Pump
125
To Connect the Alarm Output
126
To Connect the Space Cooling/Heating ON/OFF Output
126
To Connect the Power Consumption Digital Inputs
127
To Connect the Safety Thermostat (Normally Closed Contact)
127
Configuration
129
Indoor Unit
129
Overview: Configuration
129
Basic Configuration
134
Advanced Configuration/Optimisation
154
Menu Structure: Overview User Settings
177
Menu Structure: Overview Installer Settings
179
Gas Boiler
180
Overview: Configuration
180
Basic Configuration
180
Operation
190
Overview: Operation
190
Heating
190
Domestic Hot Water
190
Flow Resistance Graph for Appliance Domestic Hot Water Circuit
191
Operation Modes
191
Commissioning
194
Overview: Commissioning
194
Precautions When Commissioning
195
Checklist before Commissioning
195
Checklist During Commissioning
196
To Check the Minimum Flow Rate
197
Air Purge Function
197
To Perform a Test Run
199
To Perform an Actuator Test Run
200
Underfloor Heating Screed Dryout
201
To Perform a Gas Pressure Test
204
To Perform a Test Run on the Gas Boiler
204
Hand-Over to the User
206
Maintenance and Service
207
Maintenance Safety Precautions
207
Opening the Indoor Unit
207
Checklist for Yearly Maintenance of the Outdoor Unit
207
Checklist for Yearly Maintenance of the Indoor Unit
208
To Disassemble the Gas Boiler
209
To Clean the Inside of the Gas Boiler
212
To Assemble the Gas Boiler
213
Troubleshooting
215
Overview: Troubleshooting
215
Precautions When Troubleshooting
215
Solving Problems Based on Symptoms
216
Symptom: the Unit Is NOT Heating or Cooling as Expected
216
Symptom: the Compressor Does NOT Start (Space Heating or Domestic Water Heating)
217
Symptom: the Pump Is Making Noise (Cavitation)
217
Symptom: the Pressure Relief Valve Opens
218
Symptom: the Water Pressure Relief Valve Leaks
218
Symptom: the Space Is NOT Sufficiently Heated at Low Outdoor Temperatures
218
Symptom: the Pressure at the Tapping Point Is Temporarily Unusually High
219
Symptom: Tank Disinfection Function Is NOT Completed Correctly (AH-Error)
219
Symptom: Boiler Abnormality Detection (HJ-11 Error)
220
Symptom: Boiler/Hydrobox Combination Abnormality (UA-52 Error)
220
Symptom: the Burner Does NOT Ignite
220
Symptom: the Burner Ignites Noisily
221
Symptom: the Burner Resonates
221
Symptom: no Space Heating by the Gas Boiler
222
Symptom: the Power Is Reduced
222
Symptom: Space Heating Does NOT Reach the Temperature
222
Symptom: Hot Water Does NOT Reach the Temperature (no Tank Installed)
222
Symptom: Hot Water Does NOT Reach the Temperature (Tank Installed)
223
Solving Problems Based on Error Codes
223
Error Codes: Overview
223
Disposal
232
Overview: Disposal
232
To Pump down
232
To Start and Stop Forced Cooling
233
Technical Data
234
Piping Diagram: Outdoor Unit
234
Piping Diagram: Indoor Unit
235
Wiring Diagram: Outdoor Unit
236
Wiring Diagram: Indoor Unit
237
Wiring Diagram: Gas Boiler
243
ESP Curve: Indoor Unit
244
Technical Specifications: Gas Boiler
245
General
245
Energy-Related Products Specifications
247
Appliance Category and Supply Pressure
248
Glossary
252
Field Settings Table
253
Daikin Altherma EVLQ05+08CA Installer's Reference Manual (252 pages)
Hybrid heat pump
Brand:
Daikin
| Category:
Heat Pump
| Size: 12.29 MB
Table of Contents
Table of Contents
2
1 General Safety Precautions
6
About the Documentation
6
Meaning of Warnings and Symbols
6
For the Installer
7
General
7
Installation Site
8
Refrigerant - in Case of R410A or R32
9
Water
11
Electrical
11
Gas
13
Gas Exhaust
14
Local Legislation
14
2 About the Product
16
3 About the Documentation
18
About this Document
18
Installer Reference Guide at a Glance
19
4 About the Box
20
Overview: about the Box
20
Outdoor Unit
20
To Unpack the Outdoor Unit
20
To Remove the Accessories from the Outdoor Unit
21
Indoor Unit
22
To Unpack the Indoor Unit
22
To Remove the Accessories from the Indoor Unit
23
Gas Boiler
23
To Unpack the Gas Boiler
23
To Remove the Accessories from the Gas Boiler
24
5 About the Units and Options
26
Overview: about the Units and Options
26
Identification
26
Identification Label: Outdoor Unit
26
Identification Label: Indoor Unit
27
Identification Label: Gas Boiler
27
Combining Units and Options
29
Possible Options for the Outdoor Unit
29
Possible Options for the Indoor Unit
30
Possible Options for the Gas Boiler
33
Possible Combinations of Indoor Unit and Outdoor Unit
38
Possible Combinations of Indoor Unit and Domestic Hot Water Tank
39
6 Preparation
40
Overview: Preparation
40
Preparing the Installation Site
40
Installation Site Requirements of the Outdoor Unit
40
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
42
Installation Site Requirements of the Indoor Unit
43
Preparing Refrigerant Piping
44
Refrigerant Piping Requirements
44
Refrigerant Piping Insulation
44
Preparing Water Piping
44
Water Circuit Requirements
45
Formula to Calculate the Expansion Vessel Pre-Pressure
48
To Check the Water Volume and Flow Rate
48
Changing the Pre-Pressure of the Expansion Vessel
50
To Check the Water Volume: Examples
51
Preparing Electrical Wiring
51
About Preparing Electrical Wiring
51
About Preferential Kwh Rate Power Supply
52
Overview of Electrical Connections Except External Actuators
53
Overview of Electrical Connections for External and Internal Actuators
54
7 Installation
56
Overview: Installation
56
Opening the Units
56
About Opening the Units
56
To Open the Outdoor Unit
56
To Open the Switch Box Cover of the Indoor Unit
57
To Open the Gas Boiler
58
To Open the Switch Box Cover of the Gas Boiler
58
Mounting the Outdoor Unit
59
About Mounting the Outdoor Unit
59
Precautions When Mounting the Outdoor Unit
59
To Provide the Installation Structure
59
To Install the Outdoor Unit
62
To Provide Drainage
62
To Prevent the Outdoor Unit from Falling over
63
Mounting the Indoor Unit
64
About Mounting the Indoor Unit
64
Precautions When Mounting the Indoor Unit
64
To Install the Indoor Unit
64
Mounting the Gas Boiler
66
To Install the Gas Boiler
66
To Install the Condensate Trap
67
Condensate Pipe Work
69
Internal Connections
69
External Connections
70
Connecting the Refrigerant Piping
70
About Connecting the Refrigerant Piping
70
Precautions When Connecting the Refrigerant Piping
71
Guidelines When Connecting the Refrigerant Piping
72
Pipe Bending Guidelines
72
To Flare the Pipe End
72
To Braze the Pipe End
73
Using the Stop Valve and Service Port
74
To Connect the Refrigerant Piping to the Outdoor Unit
75
To Connect the Refrigerant Piping to the Indoor Unit
76
Checking the Refrigerant Piping
76
About Checking the Refrigerant Piping
76
Precautions When Checking the Refrigerant Piping
77
To Check for Leaks
77
To Perform Vacuum Drying
78
Charging Refrigerant
79
About Charging Refrigerant
79
Precautions When Charging Refrigerant
80
To Determine the Additional Refrigerant Amount
80
To Determine the Complete Recharge Amount
80
To Charge Additional Refrigerant
80
To Fix the Fluorinated Greenhouse Gases Label
80
Connecting Water Piping
81
About Connecting the Water Piping
81
Precautions When Connecting the Water Piping
81
Connecting the Water Piping of the Indoor Unit
82
Connecting the Water Piping of the Gas Boiler
83
To Fill the Space Heating Circuit
84
To Fill the Domestic Water Circuit of the Gas Boiler
85
To Fill the Domestic Hot Water Tank
85
To Insulate the Water Piping
85
Connecting the Electrical Wiring
86
About Connecting the Electrical Wiring
86
Precautions When Connecting the Electrical Wiring
87
Guidelines When Connecting the Electrical Wiring
87
To Connect the Electrical Wiring to the Outdoor Unit
88
To Connect the Electrical Wiring to the Indoor Unit
88
To Connect the Main Power Supply of the Indoor Unit
90
To Connect the Main Power Supply of the Gas Boiler
91
To Connect the Communication Cable between Gas Boiler and Indoor Unit
92
To Connect the User Interface
94
To Connect the Shut-Off Valve
95
To Connect the Electrical Meter
96
To Connect the Gas Meter
97
To Connect the Domestic Hot Water Pump
97
To Connect the Alarm Output
97
To Connect the Space Cooling/Heating ON/OFF Output
98
To Connect the Power Consumption Digital Inputs
98
To Connect the Safety Thermostat (Normally Closed Contact)
99
Connecting the Gas Piping
100
To Connect the Gas Pipe
100
Connecting the Boiler to the Flue Gas System
101
To Change the Gas Boiler to 80/125 Concentric Connection
101
To Change the 60/100 Concentric Connection to a Dual Pipe Connection
102
Calculate the Total Piping Length
103
Appliance Categories and Pipe Lengths
104
Applicable Materials
108
Flue Pipe Position
109
Insulation of the Gas Exhaust and Air Intake
110
Fitting a Horizontal Flue System
110
Fitting a Vertical Flue System
111
Plume Management Kit
111
Flues in Voids
112
Flue Gas Materials (C63) Available on the Market
113
About Securing the Flue System
114
Finishing the Outdoor Unit Installation
115
To Finish the Outdoor Unit Installation
115
To Close the Outdoor Unit
116
Finishing the Indoor Unit Installation
116
To Close the Indoor Unit
116
Finishing the Gas Boiler Installation
116
To Perform an Air Purge on the Gas Supply
116
To Close the Gas Boiler
117
To Install the Cover Plate
118
8 Configuration
119
Indoor Unit
119
Overview: Configuration
119
Basic Configuration
124
Advanced Configuration/Optimisation
144
Menu Structure: Overview User Settings
167
Menu Structure: Overview Installer Settings
169
Gas Boiler
170
Overview: Configuration
170
Basic Configuration
170
9 Operation
180
Overview: Operation
180
Heating
180
Domestic Hot Water
180
Flow Resistance Graph for Appliance Domestic Hot Water Circuit
181
Operation Modes
181
10 Commissioning
183
Overview: Commissioning
183
Precautions When Commissioning
183
Checklist before Commissioning
184
Checklist During Commissioning
185
To Check the Minimum Flow Rate
185
Air Purge Function
186
To Perform a Test Run
188
To Perform an Actuator Test Run
189
Underfloor Heating Screed Dryout
190
To Perform a Gas Pressure Test
192
To Perform a Test Run on the Gas Boiler
193
11 Hand-Over to the User
195
12 Maintenance and Service
196
Overview: Maintenance and Service
196
Maintenance Safety Precautions
196
Opening the Indoor Unit
196
Checklist for Yearly Maintenance of the Outdoor Unit
196
Checklist for Yearly Maintenance of the Indoor Unit
197
To Disassemble the Gas Boiler
198
To Clean the Inside of the Gas Boiler
201
To Assemble the Gas Boiler
202
13 Troubleshooting
204
Overview: Troubleshooting
204
Precautions When Troubleshooting
204
Solving Problems Based on Symptoms
205
Symptom: the Unit Is NOT Heating or Cooling as Expected
205
Symptom: the Compressor Does NOT Start (Space Heating or Domestic Water Heating)
206
Symptom: the Pump Is Making Noise (Cavitation)
206
Symptom: the Pressure Relief Valve Opens
206
Symptom: the Water Pressure Relief Valve Leaks
207
Symptom: the Space Is NOT Sufficiently Heated at Low Outdoor Temperatures
207
Symptom: the Pressure at the Tapping Point Is Temporarily Unusually High
208
Symptom: Tank Disinfection Function Is NOT Completed Correctly (AH-Error)
208
Symptom: Boiler Abnormality Detection (HJ-11 Error)
209
Symptom: Boiler/Hydrobox Combination Abnormality (UA-52 Error)
209
Symptom: the Burner Does NOT Ignite
209
Symptom: the Burner Ignites Noisily
210
Symptom: the Burner Resonates
210
Symptom: no Space Heating by the Gas Boiler
210
Symptom: the Power Is Reduced
211
Symptom: Space Heating Does NOT Reach the Temperature
211
Symptom: Hot Water Does NOT Reach the Temperature (no Tank Installed)
211
Symptom: Hot Water Does NOT Reach the Temperature (Tank Installed)
211
Solving Problems Based on Error Codes
212
Error Codes: Overview
212
14 Disposal
220
Overview: Disposal
220
To Pump down
220
To Start and Stop Forced Cooling
221
15 Technical Data
222
Piping Diagram: Outdoor Unit
222
Piping Diagram: Indoor Unit
223
Wiring Diagram: Outdoor Unit
224
Wiring Diagram: Indoor Unit
225
Wiring Diagram: Gas Boiler
231
ESP Curve: Indoor Unit
232
Technical Specifications: Gas Boiler
233
General
233
Energy-Related Products Specifications
235
Appliance Category and Supply Pressure
236
16 Glossary
240
17 Field Settings Table
241
Related Products
Daikin Altherma EVLQ05
Daikin Altherma EVLQ05CAV3
Daikin Altherma EVLQ08CAV3
Daikin EHVH/X04+08S18CA
Daikin EWAA014DAV3P-H
Daikin EHVH08S23EJ9W
Daikin EWSAX06UD 9W Series
Daikin Altherma ERRA10E W1 Series
Daikin EBVZ-D6V
Daikin EHVH04S18DA6VG
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals