beautypg.com
Manuals
Brands
Daikin Manuals
Air Conditioner
ARXTP25R2V1B
Daikin ARXTP25R2V1B Manuals
Manuals and User Guides for Daikin ARXTP25R2V1B. We have
3
Daikin ARXTP25R2V1B manuals available for free PDF download: Service Manual, Installer's Reference Manual, Installation Manual
Daikin ARXTP25R2V1B Service Manual (264 pages)
R32 Optimized Heating 4 Split
Brand:
Daikin
| Category:
Air Conditioner
| Size: 63.3 MB
Table of Contents
Table of Contents
4
Safety Precautions
7
Meaning of Warnings and Symbols
7
Dangers
8
Warnings
8
Cautions
14
Notices
14
General Operation
15
Troubleshooting
16
To Display the Error Code on the User Interface
16
To Reset the Error Code Via Remote Controller
16
To Reset the Error Code Via Outdoor Unit
16
To Perform a Test Run
16
To Perform a Test Run in Winter Season
17
To Perform a Test Run Using the User Interface
17
Error Based Troubleshooting
17
A1-00 - PCB Abnormality
17
A5-00 - Outdoor Unit: High Pressure Peak Cut / Freeze Protection Problem
18
A6-00 - Indoor Unit Fan Motor Abnormality
19
Streamer Unit Abnormality
19
C4-00 - Heat Exchanger Temperature Sensor Problem
20
C9-00 - Room Thermistor Abnormality
20
Humidity Sensor Abnormality
21
Intelligent Thermal Sensor Abnormality
21
E1-00 - Outdoor Unit: PCB Defect
22
E3-00 - Outdoor Unit: Actuation of High Pressure Switch
23
E5-00 - Outdoor Unit: Overheat of Inverter Compressor Motor
24
E6-00 - Outdoor Unit: Compressor Startup Defect
25
E7-00 - Outdoor Unit: Malfunction of Outdoor Unit Fan Motor
26
E8-00 - Outdoor Unit: Power Input Overvoltage
26
Outdoor Unit: Cool/Heat Switchover Problem
27
F3-00 - Outdoor Unit: Malfunction of Discharge Pipe Temperature
28
F6-00 - Outdoor Unit: Abnormal High Pressure in Cooling
29
F8-00 - System Shutdown Due to Compressor Internal Temperature Abnormality
29
H0-00 - Outdoor Unit: Voltage/Current Sensor Problem
30
H3-00 - Outdoor Unit: Malfunction of High Pressure Switch
31
H6-00 - Outdoor Unit: Malfunction of Position Detection Sensor
32
H8-00 - Outdoor Unit: Malfunction of Compressor Input System
33
H9-00 - Outdoor Unit: Malfunction of Outdoor Air Thermistor
33
J3-00 - Outdoor Unit: Malfunction of Discharge Pipe Thermistor
34
J6-00 - Outdoor Unit: Malfunction of Heat Exchanger Thermistor
34
L3-00 - Outdoor Unit: Electrical Box Temperature Rise Problem
34
L4-00 - Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise
35
L5-00 - Outdoor Unit: Inverter Instantaneous Overcurrent
36
P4-00 - Outdoor Unit: Malfunction of Radiating Fin Temperature Sensor
37
U0-00 - Outdoor Unit: Shortage of Refrigerant
37
U2-00 - Outdoor Unit: Defect of Power Supply Voltage
38
U4-00 - Indoor/Outdoor Unit Communication Problem
39
Indoor Unit, Outdoor Unit Mismatching Problem
40
Symptom Based Troubleshooting
42
Operation Does Not Start
42
Operation Sometimes Stops
42
Operation Starts but the Unit Does Not Cool/Heat
43
Operating Noise and Vibrations
44
Abnormal High Pressure
45
Abnormal Low Pressure
46
Indoor Fan Starts Operating but the Compressor Does Not Operate
47
Operation Starts and the Unit Stops Immediately
48
Operation Stops, Unit Cannot Start for a While
48
Unit Discharges White Mist
49
Humidifying Problem
49
Swing Flap Does Not Operate
49
Components
50
4-Way Valve
50
Checking Procedures
50
Repair Procedures
53
Compressor
57
Checking Procedures
57
Repair Procedures
62
Compressor Thermal Protector
68
Checking Procedures
68
Repair Procedures
69
Expansion Valve
72
Checking Procedures
72
Repair Procedures
76
Front Panel Motor
79
Checking Procedures
79
Repair Procedures
81
High Pressure Switch
83
Checking Procedures
83
Repair Procedures
84
Humidity Sensor
86
Checking Procedures
86
Repair Procedures
87
Indoor Unit Fan Motor
89
Checking Procedures
89
Repair Procedures
90
Indoor Unit Heat Exchanger
94
Checking Procedures
94
Repair Procedures
95
Indoor Unit Main PCB
97
Checking Procedures
97
Repair Procedures
103
Indoor Unit Power PCB
109
Checking Procedures
109
Repair Procedures
113
Intelligent Eye Sensor
118
Checking Procedures
118
Repair Procedures
120
Intelligent Thermal Sensor
122
Checking Procedures
122
Repair Procedures
123
Main PCB
126
Checking Procedures
126
Repair Procedures
132
Outdoor Unit Fan Motor
135
Checking Procedures
135
Repair Procedures
138
Outdoor Unit Heat Exchanger
141
Checking Procedures
141
Repair Procedures
142
Plate Work
144
Outdoor Unit
144
Indoor Unit
151
Reactor
165
Checking Procedures
165
Repair Procedures
167
Streamer Unit
167
Checking Procedures
167
Swing Flap Motor
170
Main Swing Flap Motor
170
Secondary Swing Flap Motor
180
Swing Raster Motor
184
Checking Procedures
184
Repair Procedures
186
Thermistors
195
Checking Procedures
195
Repair Procedures
200
Wifi Control PCB
205
Checking Procedures
205
Repair Procedures
206
Third Party Components
209
Electrical Circuit
209
Checking Procedures
209
Repair Procedures
210
Refrigerant Circuit
211
Checking Procedures
211
Repair Procedures
216
External Factors
220
Checking Procedures
220
Maintenance
222
To Clean the Outdoor Unit Heat Exchanger
222
To Clean the Indoor Unit Heat Exchanger
222
To Clean the Indoor Unit Heat Exchanger in Extreme Condition
223
To Clean the Indoor Unit and Wireless Remote Control
223
To Clean the Front Panel
224
To Clean the Air Filters
224
To Clean the Titanium Apatite Deodorising Filter and the Silver Particle Filter (Ag-Ion Filter)
227
To Replace the Titanium Apatite Deodorising Filter and the Silver Particle Filter (Ag-Ion Filter)
229
Technical Data
231
Detailed Information Setting Mode
231
Detailed Information Setting Mode: Indoor Unit
231
Detailed Information Setting Mode: Outdoor Unit
231
Detailed Information Setting Mode: Remote Controller
231
Wiring Diagram
232
Wiring Diagram: Outdoor Unit
232
Wiring Diagram: Indoor Unit
235
Piping Diagram
242
Piping Diagram: Outdoor Unit
242
Piping Diagram: Indoor Unit
243
Component Overview
248
Component Overview: Outdoor Unit
248
Component Overview: Indoor Unit
249
Field Information Report
253
Service Tools
256
Field Settings
257
Field Settings: Indoor Unit
257
Field Settings: Outdoor Unit
260
Daikin ARXTP25R2V1B Installer's Reference Manual (68 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 4.87 MB
Table of Contents
Table of Contents
2
About the Documentation
4
About this Document
4
Meaning of Warnings and Symbols
5
General Safety Precautions
7
For the Installer
7
General
7
Installation Site
8
Refrigerant - in Case of R410A or R32
11
Electrical
12
Specific Installer Safety Instructions
15
About the Box
21
Overview: about the Box
21
Outdoor Unit
21
To Unpack the Outdoor Unit
21
To Handle the Outdoor Unit
21
To Remove the Accessories from the Outdoor Unit
22
About the Unit
23
Identification
23
Identification Label: Outdoor Unit
23
Unit Installation
24
Preparing the Installation Site
24
Installation Site Requirements of the Outdoor Unit
25
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
27
Opening the Unit
28
About Opening the Unit
28
To Open the Outdoor Unit
28
Mounting the Outdoor Unit
28
About Mounting the Outdoor Unit
28
Precautions When Mounting the Outdoor Unit
29
To Provide the Installation Structure
29
To Install the Outdoor Unit
30
To Provide Drainage
30
To Prevent the Outdoor Unit from Falling over
30
Piping Installation
32
Preparing Refrigerant Piping
32
Refrigerant Piping Requirements
32
Refrigerant Piping Insulation
33
Refrigerant Piping Length and Height Difference
33
Connecting the Refrigerant Piping
33
About Connecting the Refrigerant Piping
33
Precautions When Connecting the Refrigerant Piping
34
Guidelines When Connecting the Refrigerant Piping
35
Pipe Bending Guidelines
36
To Flare the Pipe End
36
Using the Stop Valve and Service Port
36
To Connect the Refrigerant Piping to the Outdoor Unit
38
Checking the Refrigerant Piping
38
About Checking the Refrigerant Piping
38
Precautions When Checking the Refrigerant Piping
39
To Check for Leaks
39
To Perform Vacuum Drying
40
Notice
40
Charging Refrigerant
42
About Charging Refrigerant
42
About the Refrigerant
43
Precautions When Charging Refrigerant
44
To Determine the Additional Refrigerant Amount
44
To Determine the Complete Recharge Amount
44
To Charge Additional Refrigerant
44
To Fix the Fluorinated Greenhouse Gases Label
45
Electrical Installation
46
About Connecting the Electrical Wiring
46
Precautions When Connecting the Electrical Wiring
46
Guidelines When Connecting the Electrical Wiring
48
Specifications of Standard Wiring Components
49
To Connect the Electrical Wiring to the Outdoor Unit
49
Finishing the Outdoor Unit Installation
51
To Finish the Outdoor Unit Installation
51
Closing the Unit
51
To Close the Outdoor Unit
51
Configuration
52
Facility Setting
52
To Set the Facility Mode
52
Commissioning
53
Overview: Commissioning
53
Precautions When Commissioning
53
Checklist before Commissioning
54
Checklist During Commissioning
54
To Perform a Test Run
54
Starting up the Outdoor Unit
55
Hand-Over to the User
56
Maintenance and Service
57
Overview: Maintenance and Service
57
Maintenance Safety Precautions
57
Checklist for Yearly Maintenance of the Outdoor Unit
58
About the Compressor
58
Winter Season
58
Troubleshooting
59
Overview: Troubleshooting
59
Precautions When Troubleshooting
59
Solving Problems Based on Symptoms
59
Symptom: Indoor Units Fall, Vibrate or Make Noise
59
Symptom: the Unit Is NOT Heating or Cooling as Expected
60
Symptom: Water Leakage
60
Symptom: Electrical Leakage
60
Symptom: Unit Does NOT Function or Burn Damage
60
Fault Diagnosis Using LED on Outdoor Unit PCB
60
Disposal
61
Overview: Disposal
61
To Pump down
61
To Start and Stop Forced Cooling
62
To Start and Stop Forced Cooling Using the Indoor Unit ON/OFF Switch
62
To Start and Stop Forced Cooling Using the Indoor Unit User Interface
62
Technical Data
63
Wiring Diagram
63
Unified Wiring Diagram Legend
63
Piping Diagram
66
Piping Diagram: Outdoor Unit
66
Glossary
67
Daikin ARXTP25R2V1B Installation Manual (20 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.37 MB
Table of Contents
Table of Contents
1
Table of Contents
4
About the Documentation
4
About this Document
4
Specific Installer Safety Instructions
4
About the Box
7
Outdoor Unit
7
To Handle the Outdoor Unit
7
To Remove the Accessories from the Outdoor Unit
7
Unit Installation
7
Preparing the Installation Site
7
Installation Site Requirements of the Outdoor Unit
7
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
8
Mounting the Outdoor Unit
8
To Provide the Installation Structure
8
To Install the Outdoor Unit
8
To Provide Drainage
8
Piping Installation
8
Preparing Refrigerant Piping
8
Refrigerant Piping Requirements
8
Refrigerant Piping Insulation
9
Refrigerant Piping Length and Height Difference
9
Connecting the Refrigerant Piping
9
To Connect the Refrigerant Piping to the Outdoor Unit
9
Checking the Refrigerant Piping
10
To Check for Leaks
10
To Perform Vacuum Drying
10
Charging Refrigerant
10
About the Refrigerant
10
To Determine the Additional Refrigerant Amount
10
To Determine the Complete Recharge Amount
11
To Charge Additional Refrigerant
11
To Fix the Fluorinated Greenhouse Gases Label
11
Electrical Installation
11
Specifications of Standard Wiring Components
12
To Connect the Electrical Wiring to the Outdoor Unit
12
Finishing the Outdoor Unit Installation
12
To Finish the Outdoor Unit Installation
12
Configuration
12
Facility Setting
12
To Set the Facility Mode
12
Commissioning
13
Checklist before Commissioning
13
Checklist During Commissioning
13
To Perform a Test Run
13
Maintenance and Service
13
Winter Season
14
Disposal 14
14
Technical Data
14
Wiring Diagram
14
Unified Wiring Diagram Legend
14
Piping Diagram
16
Piping Diagram: Outdoor Unit
16
Related Products
Daikin ARXTP25N2V1B
Daikin ARXTP25-35N
Daikin ARXTP35N2V1B
Daikin ARXTP35R2V1B
Daikin ARXTP-N
Daikin ARXS50E2V1B
Daikin ARXV60AV1B
Daikin ARXQ25AMV1B
Daikin ARXN25N5V1B9
Daikin ARX25K5V1B9
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals