beautypg.com
Manuals
Brands
Daikin Manuals
Air Conditioner
ATXQ35AMV1B
Daikin ATXQ35AMV1B Manuals
Manuals and User Guides for Daikin ATXQ35AMV1B. We have
2
Daikin ATXQ35AMV1B manuals available for free PDF download: Service Manual, Installer's Reference Manual
Daikin ATXQ35AMV1B Service Manual (152 pages)
Split R32 BBOP
Brand:
Daikin
| Category:
Air Conditioner
| Size: 25.38 MB
Table of Contents
Table of Contents
4
Safety Precautions
6
Meaning of Warnings and Symbols
6
Dangers
7
Warnings
7
Cautions
13
Notices
13
Troubleshooting
14
To Display the Error Code on the User Interface
14
To Reset the Error Code Via Remote Controller
14
To Reset the Error Code Via Outdoor Unit
14
To Perform a Test Run
14
To Perform a Test Run in Winter Season
15
Error Based Troubleshooting
15
A1-00 - PCB Abnormality
15
A5-00 - Outdoor Unit: High Pressure Peak Cut / Freeze Protection Problem
16
A6-00 - Indoor Unit Fan Motor Abnormality
17
C4-00 - Heat Exchanger Temperature Sensor Problem
17
C9-00 - Room Thermistor Abnormality
18
E1-00 - Outdoor Unit: PCB Defect
18
E5-00 - Outdoor Unit: Overheat of Inverter Compressor Motor
19
E6-00 - Outdoor Unit: Compressor Startup Defect
20
E7-00 - Outdoor Unit: Malfunction of Outdoor Unit Fan Motor
21
E8-00 - Outdoor Unit: Power Input Overvoltage
21
Outdoor Unit: Cool/Heat Switchover Problem
22
F3-00 - Outdoor Unit: Malfunction of Discharge Pipe Temperature
23
F6-00 - Outdoor Unit: Abnormal High Pressure in Cooling
24
F8-00 - System Shutdown Due to Compressor Internal Temperature Abnormality
25
H0-00 - Outdoor Unit: Voltage/Current Sensor Problem
25
H6-00 - Outdoor Unit: Malfunction of Position Detection Sensor
26
H8-00 - Outdoor Unit: Malfunction of Compressor Input System
27
H9-00 - Outdoor Unit: Malfunction of Outdoor Air Thermistor
28
J3-00 - Outdoor Unit: Malfunction of Discharge Pipe Thermistor
28
J6-00 - Outdoor Unit: Malfunction of Heat Exchanger Thermistor
28
L3-00 - Outdoor Unit: Electrical Box Temperature Rise Problem
29
L4-00 - Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise
30
L5-00 - Outdoor Unit: Inverter Instantaneous Overcurrent
30
P4-00 - Outdoor Unit: Malfunction of Radiating Fin Temperature Sensor
32
U0-00 - Outdoor Unit: Shortage of Refrigerant
32
U2-00 - Outdoor Unit: Defect of Power Supply Voltage
33
U4-00 - Indoor/Outdoor Unit Communication Problem
34
Indoor Unit, Outdoor Unit Mismatching Problem
35
Symptom Based Troubleshooting
36
Operation Does Not Start
36
Operation Sometimes Stops
36
Operation Starts but the Unit Does Not Cool/Heat
37
Operating Noise and Vibrations
38
Abnormal High Pressure
39
Abnormal Low Pressure
40
Indoor Fan Starts Operating but the Compressor Does Not Operate
41
Operation Starts and the Unit Stops Immediately
42
Operation Stops, Unit Cannot Start for a While
42
Unit Discharges White Mist
43
Swing Flap Does Not Operate
43
Components
44
4-Way Valve
44
Checking Procedures
44
Repair Procedures
47
Compressor
50
Checking Procedures
50
Repair Procedures
56
Compressor Thermal Protector
61
Checking Procedures
61
Repair Procedures
62
Expansion Valve
65
Checking Procedures
65
Repair Procedures
69
Indoor Unit Fan Motor
72
Checking Procedures
72
Repair Procedures
73
Indoor Unit Main PCB
74
Checking Procedures
74
Repair Procedures
77
Inverter PCB
80
Checking Procedures
80
Repair Procedures
81
Main PCB
81
Checking Procedures
81
Repair Procedures
89
Outdoor Unit Fan Motor
90
Checking Procedures
90
Repair Procedures
92
Plate Work
94
Outdoor Unit
94
Indoor Unit
100
Reactor
104
Checking Procedures
104
Repair Procedures
105
Swing Flap Motor
106
Checking Procedures
106
Repair Procedures
107
Thermistors
108
Refrigerant Side Thermistors
108
Other Thermistors
115
Third Party Components
118
Electrical Circuit
118
Checking Procedures
118
Repair Procedures
119
Refrigerant Circuit
120
Checking Procedures
120
Repair Procedures
124
External Factors
127
Checking Procedures
127
Maintenance
129
To Clean the Outdoor Unit Heat Exchanger
129
To Clean the Indoor Unit Heat Exchanger
129
To Clean the Indoor Unit Heat Exchanger in Extreme Condition
130
To Clean the Front Panel
130
To Clean the Air Filters
130
Technical Data
132
Detailed Information Setting Mode
132
Detailed Information Setting Mode: Indoor Unit
132
Detailed Information Setting Mode: Outdoor Unit
132
Detailed Information Setting Mode: Remote Controller
132
Wiring Diagram
133
Wiring Diagram: Indoor Unit
133
Wiring Diagram: Outdoor Unit
137
Piping Diagram
141
Piping Diagram: Indoor Unit
141
Piping Diagram: Outdoor Unit
142
Component Overview
144
Component Overview: Indoor Unit
144
Component Overview: Outdoor Unit
145
Field Information Report
146
Service Tools
149
Field Settings
150
Field Settings: Indoor Unit
150
Field Settings: Outdoor Unit
151
Daikin ATXQ35AMV1B Installer's Reference Manual (52 pages)
room air conditioner
Brand:
Daikin
| Category:
Air Conditioner
| Size: 5.08 MB
Table of Contents
Table of Contents
2
1 About the Documentation
4
About this Document
4
Meaning of Warnings and Symbols
5
2 General Safety Precautions
7
For the Installer
7
General
7
Installation Site
8
Refrigerant - in Case of R410A or R32
11
Electrical
12
3 Specific Installer Safety Instructions
15
4 About the Box
17
Overview: about the Box
17
Indoor Unit
17
To Unpack the Indoor Unit
17
To Remove the Accessories from the Indoor Unit
17
5 About the Unit
19
System Layout
19
Operation Range
19
6 Unit Installation
20
Preparing the Installation Site
20
Installation Site Requirements of the Indoor Unit
20
Opening the Unit
21
To Remove the Front Panel
21
To Open the Service Cover
22
To Remove the Front Grille
22
To Remove the Electrical Wiring Box Cover
23
Mounting the Indoor Unit
23
To Install the Mounting Plate
23
To Remove the Front Grille
23
To Drill a Wall Hole
24
To Remove the Pipe Port Cover
25
Connecting the Drain Piping
25
General Guidelines
25
To Connect the Piping on Right Side, Right-Back, or Right-Bottom
25
To Connect the Piping on Left Side, Left-Back, or Left-Bottom
25
To Check for Water Leaks
25
General Guidelines
26
To Connect the Piping on Right Side, Right-Back, or Right-Bottom
27
To Connect the Piping on Left Side, Left-Back, or Left-Bottom
27
To Check for Water Leaks
28
7 Piping Installation
29
Preparing Refrigerant Piping
29
Refrigerant Piping Requirements
29
Refrigerant Piping Insulation
30
Connecting the Refrigerant Piping
30
About Connecting the Refrigerant Piping
30
Precautions When Connecting the Refrigerant Piping
30
Preparing Refrigerant Piping
30
Pipe Bending Guidelines
30
Guidelines When Connecting the Refrigerant Piping
31
Pipe Bending Guidelines
32
To Flare the Pipe End
32
To Connect the Refrigerant Piping to the Indoor Unit
33
8 Electrical Installation
34
About Connecting the Electrical Wiring
34
Precautions When Connecting the Electrical Wiring
34
Guidelines When Connecting the Electrical Wiring
35
Specifications of Standard Wiring Components
36
To Connect the Electrical Wiring to the Indoor Unit
36
9 Finishing the Indoor Unit Installation
39
To Insulate the Drain Piping, Refrigerant Piping and Interconnection Cable
39
To Pass the Pipes through the Wall Hole
39
To Fix the Unit on the Mounting Plate
40
Closing the Unit
40
To Close the Electrical Wiring Box Cover
40
To Re-Install the Front Grille
40
To Close the Service Cover
40
To Re-Install the Front Panel
41
10 Configuration
42
To Set a Different Address
42
11 Commissioning
44
Overview: Commissioning
44
Checklist before Commissioning
44
To Perform a Test Run
45
To Perform a Test Run in Winter Season
45
12 Hand-Over to the User
46
13 Disposal
47
14 Technical Data
48
Wiring Diagram
48
Unified Wiring Diagram Legend
48
15 Glossary
51
Related Products
Daikin ATXQ25AMV1B
Daikin ATXS25K3V1B
DAIKIN ATXP35K2V1B
Daikin ATXM50M2V1B
Daikin ATXN50N
Daikin Siesta ATXP25L2V1B
Daikin Siesta ATXN60LV1B
Daikin Siesta ATXM20R2V1B
Daikin Siesta ATXC25AV1B9
Daikin ATXF35E5V1B
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals