beautypg.com
Manuals
Brands
Eaton Manuals
Circuit breakers
120W-VAC16
Eaton 120W-VAC16 Manuals
Manuals and User Guides for Eaton 120W-VAC16. We have
2
Eaton 120W-VAC16 manuals available for free PDF download: Instructions For Installation, Operation And Maintenance
Eaton 120W-VAC16 Instructions For Installation, Operation And Maintenance (62 pages)
Vacuum Circuit Breaker
Brand:
Eaton
| Category:
Circuit breakers
| Size: 6.48 MB
Table of Contents
Table of Contents
4
Figure Title
9
Type W-VACR 630A Breaker Element Only Outline Dimensions (Millimeters) & Weights (Kilograms)
9
Type W-VACR 630A Breaker Element Only Outline Dimensions (Millimeters) & Weights (Kilograms)
10
Type W-VACR 800/1250A Breaker Element Only Outline Dimensions (Millimeters) & Weights (Kg)
11
Type W-VACR 800/1250A Breaker Element Only Outline Dimensions (Millimeters) & Weights (Kg)
12
Type W-VACR 800/1250A Breaker Element Only Outline Dimensions (Millimeters) & Weights (Kg)
13
Type W-VACR 2000A Breaker Element Only Outline Dimensions (Millimeters) & Weights (Kg)
14
Type W-VACR 2500A Breaker Element Only Outline Dimensions (Millimeters) & Weights (Kg)
15
Type W-VAC Breaker Element Only Outline Dimensions (Millimeters) and Weights (Kilograms)
16
Outline and Dimensions (MM) Type W-VAC Breaker Element with Carriage Assembly and Cradle Assembly
17
Outline and Dimensions (MM) Type W-VAC 3150 Breaker with Carriage Assembly
18
Section 2 Safe Practices
19
Section 3 Receiving, Handling and Storage
20
Receiving
20
Typical VCP-W Tools and Accessories
20
Handling
21
Storage
21
Typical Front View VCP-W Vacuum Circuit Breaker Element
22
Typical VCP-W Vacuum Circuit Breaker Element with Front Cover Removed
23
Typical Rear View VCP-W Vacuum Circuit Breaker Element
24
Typical VCP-W Vacuum Circuit Breaker Element Escutcheon
25
Front and Rear External View W-VAC Breaker with Cradle Assembly for Double Tier Switchgear
26
Front and Rear External View W-VAC 3150A Breaker with Carriage Assembly for Single Tier Switchgear
27
Section 4 Installation
28
Initial Inspection and Operation
28
Manual Operation Check
28
Vacuum Interrupter Integrity
28
Insulation
28
Contact Erosion and Wipe
28
Primary Circuit Resistance
28
Nameplate
28
Electrical Operations Check
28
Type W-VAC Breaker Manual Operation (Single Tier Breaker Shown)
29
Breaker/Compartment Interface Check
30
Section 5 Description and Operation
32
Interrupter Assembly
32
5-1.1 Vacuum Interrupter
32
Flush Mounted Configuration
32
5-1.2 Contact Erosion Indicator (Except 3150A)
33
5-1.3 Contact Erosion Indicator (3150A Only)
33
Behind the Door Configuration
33
Closeup of Type W-VAC Breaker Vacuum Interrupters and Current Carrying System
33
5-1.4 "T" Cutout Loading Spring Indicator
34
5-1.5 Contact Wipe and Stroke
34
5-1.6 Pole Unit Support Molding
34
Stored Energy Mechanism
35
5-2.1 Operation of Stored Energy Mechanism
35
5-2.2 Charging
35
5-2.3 Closing Operation
35
Closing Cam and Trip Linkage
36
Charging Schematic
37
5-2.4 Tripping Operation
38
5-2.5 Trip Free Operation
38
Control Scheme
38
5-3.1 Timing
38
5-3.2 Secondary Disconnects
38
5-3.3 Undervoltage Trip Device
39
Interlocks
39
5-4.1 Floor Tripping, Spring Release and Anti-Latch Interlocks
39
5-4.2 Levering Interlock
39
5-4.3 Anti-Close Interlock
39
5-4.4 Earthing Drive Interlock
39
Typical DC and AC Control Schemes
40
Undervoltage Trip Device Configuration
41
Miscellaneous
42
5-5.1 Earthing Contact
42
5-5.2 Operations Counter
42
Levering Mechanism
42
Circuit Breaker Interfacing
42
5-7.1 Electrical Clearances
42
Closeup of Type W-VACW Breaker Vacuum Interrupters and Current Carrying System
42
Section 6 Inspection and Maintenance
43
Warning
43
Frequency of Inspection
43
Vacuum Interrupter Integrity Test
43
Lubrication Points
43
Inspection and Maintenance Procedures
44
Contact Erosion (Except 3150A)
46
6-5.1 Contact Erosion (3150A Only)
46
6-5.2 Contact Wipe (All Ratings)
46
Vacuum Interrupter Showing Contact Erosion Indicator with Breaker Open
46
Vacuum Interrupter Showing Contact Erosion Indicator with Breaker Closed
46
Insulation
47
Insulation Integrity Check
47
Breaker Shown Closed and Interrupter Erosion Satisfactory (3150A)
47
Primary Circuit Resistance Check
48
Mechanism Check
48
6-9.1 Closure Test
48
T" Contact Wipe Indicator
48
Lubrication
53
Troubleshooting Chart
53
Section 7 Renewal Parts
56
General
56
Ordering Instructions
56
Eaton 120W-VAC16 Instructions For Installation, Operation And Maintenance (48 pages)
Vacuum Circuit Breakers
Brand:
Eaton
| Category:
Circuit breakers
| Size: 0.74 MB
Table of Contents
Table of Contents
4
Section 1 Introduction
7
Table 1.1 Type W-VAC Vacuum Circuit Breaker Ratings
7
Type W-VAC Breaker Ratings
7
Figure Title
8
Type W-VAC Breaker Element Only Outline Dimensions (Millimeters) and Weights (Kilograms)
8
Outline and Dimensions (MM) Type W-VAC Breaker Element with Carriage Assembly and Cradle Assembly
9
Section 2 Safe Practices
10
Section 3 Receiving, Handling and Storage
11
Receiving
11
Front and Rear External View W-VAC Breaker with Cradle Assembly for
17
Section 4 Installation
18
Initial Inspection and Operation
18
Manual Operation Check
18
Vacuum Interrupter Integrity
18
Insulation
18
Contact Erosion and Wipe
18
Primary Circuit Resistance
18
Nameplate
18
Electrical Operations Check
18
Type W-VAC Breaker Manual Operation (Single Tier Breaker Shown)
19
Breaker/Compartment Interface Check
20
Section 5 Description and Operation
22
Interrupter Assembly
22
5-1.1 Vacuum Interrupter
22
Flush Mounted Configuration
22
5-1.2 Contact Erosion Indicator
23
5-1.3 "T" Cutout Loading Spring Indicator
23
5-1.4 Contact Wipe and Stroke
23
Behind the Door Configuration
23
5-1.5 Pole Unit Support Molding
24
Stored Energy Mechanism
24
5-2.1 Operation of Stored Energy Mechanism
24
Type W-VAC 95 Kv BIL Breaker Shown with Left Hand Cover Removed for Clarity Purposes
24
5-2.2 Charging
25
5-2.3 Closing Operation
25
5-2.4 Tripping Operation
25
5-2.5 Trip Free Operation
25
Control Scheme
25
Closing Cam and Trip Linkage
26
Charging Schematic
27
5-3.1 Timing
28
5-3.2 Secondary Disconnects
28
5-3.3 Undervoltage Trip Device
28
Interlocks
29
5-4.1 Floor Tripping, Spring Release and Anti-Latch Interlocks
29
5-4.2 Levering Interlock
29
5-4.3 Anti-Close Interlock
29
5-4.4 Earthing Drive Interlock
29
Miscellaneous
29
5-5.1 Earthing Contact
29
5-5.2 Operations Counter
29
Levering Mechanism
29
Undervoltage Trip Device Configuration
31
Section 6 Inspection and Maintenance
32
Warning
32
Frequency
32
Lubrication Points
32
Inspection and Maintenance Procedures
33
Vacuum Interrupter Integrity Test
34
Contact Erosion and Wipe
34
Insulation
35
Insulation Integrity Check
35
Vacuum Interrupter Showing Contact Erosion Indicator with Breaker Open
35
Vacuum Interrupter Showing Contact Erosion Indicator with Breaker Closed
35
Primary Circuit Resistance Check
36
Mechanism Check
36
Lubrication
36
T" Contact Wipe Indicator
36
Troubleshooting Chart
38
Section 7 Renewal Parts
41
General
41
Ordering Instructions
41
Related Products
Eaton 120W-VAC32
Eaton 120W-VAC40
Eaton 120W-VAC50
Eaton 120W-VACW25
Eaton 120W-VACW16
Eaton 120W-VACW40
Eaton 120W-VACW32
Eaton 120W-VACR25
Eaton 120W-VACR32
Eaton 120W-VACR40
Eaton Categories
UPS
Circuit breakers
Industrial Equipment
Switch
Industrial Electrical
More Eaton Manuals