beautypg.com
Manuals
Brands
Franklin Electric Manuals
DC Drives
Cerus X-Drive
Franklin Electric Cerus X-Drive Manuals
Manuals and User Guides for Franklin Electric Cerus X-Drive. We have
3
Franklin Electric Cerus X-Drive manuals available for free PDF download: Installation And Operation Manual, Quick Start Manual
Franklin Electric Cerus X-Drive Installation And Operation Manual (156 pages)
Brand:
Franklin Electric
| Category:
DC Drives
| Size: 13.61 MB
Table of Contents
Table of Contents
5
Product Information
11
Description
11
Features
11
Models
12
Unpacking and Inspection
13
Transportation and Storage
13
Unpacking
13
Installation Planning
15
Basic VFD Configuration
16
Physical Installation
17
Environmental Requirements
17
Mounting the Drive
18
Mounting Frames A, B, and C
19
Mounting Frames D0, D, and E
19
Mounting Frames F, G, and H
19
Conduit Box Installation
20
Frames D0 and D Conduit Box Installation
20
Frame E Conduit Box Installation
21
Frame F Conduit Box Installation
22
Frame G Conduit Box Installation
23
Frame H Conduit Box Installation
24
Drive Dimensions
26
Electrical Installation
33
Wiring Guidelines
33
Branch Circuit Protection
34
Fuse and Circuit Breaker Sizing
34
Wire Sizing
36
Motor Cable Lengths for Submersible Pumping Applications
36
Suggested Maximum Motor Cable Lengths for Non-Submersible Applications
37
Power Wiring Connections
39
Power Wiring Diagram
39
Control Circuit Connections
41
Terminal Identification
41
Example Configurations
43
4-20Ma Speed Control Signal from an External BMS or PLC
43
0-10V Speed Control Signal from an External BMS or PLC
43
4-20Ma Transducer with VFD 10 VDC Power
43
4-20Ma Transducer with VFD 24 VDC Power
43
4-20Ma Transducer with External 24 VDC Power
44
0-10VDC Transducer with VFD 10 VDC Power
44
0-10VDC Transducer with VFD 24 VDC Power
44
0-10VDC Transducer with External 24 VDC Power
44
Temperature Protection or PID Control with PT-100 or PTC Sensor
45
Speed Control Using 0-10 VDC Potentiometer
45
NPN and PNP Digital Inputs Configuration
46
Drive Programming
47
Using the Keypad
47
Home Screen Display Options
47
Setting Operating Parameters
48
Enter Required Parameters before Starting VFD
48
Verify Default Settings
48
Verify Control Terminal Settings
49
Enter or Verify Optional Settings
49
Default Settings Tables
50
Default Settings Table - SET Menu
50
Default Settings Table - VFD Menu
51
Default Settings Table - I/O Menu
52
Default Settings Table - ADV Menu
54
Default Settings Table - PROT Menu
54
Default Settings Table - COMM Menu
56
Default Settings Table - PLC Menu
57
Default Settings Table - Option Menu
58
Default Settings Table - ADV2 Menu
59
Default Settings Table - Motor Menu
60
Installation Testing
61
Rotation Check
61
Feedback Checks
61
Performance Checks
61
Sleep Mode Check (Pump Applications)
62
Operation
63
Control Options
63
Hand/Auto Controls
63
Forward or Reverse Selection
64
Jog Feature
64
Step Frequencies
65
Shutdown
65
Standard Operation with an Automated Control System
66
Standard Operation with PID Feedback Control
66
Damper Control (HVAC Applications)
67
Fireman's Override
67
Pump Application Features
68
Sleep Mode with Pressure Boost
68
Pipe Fill Feature
68
Lubrication Relay
69
Screen Clean Relay
70
Timers
70
Power on Run Delay
70
Run Delay Timer (for Auto Mode)
70
Minimum Run Timer
70
Backspin Timer
71
Performance Control Features
71
Acceleration/Deceleration Control
71
Monitoring Functions
72
Home Screen Status Displays
72
View Screens
73
Protection Features
75
High Load Detection
75
Underload Protection (Dry Well or Belt Loss)
76
Overpressure
77
No Flow Protection
78
Broken Pipe Protection (for Pump Applications)
78
Advanced Application Options
79
Operation with Permanent Magnet Motors
79
Setup Magforce Pump Motor
80
Basic Setup
80
Permanent Magnet Specific Parameters
80
Motor Specific Parameters
81
Autotune Characteristic Parameters
81
Tune Motor Control - DC Alignment
81
Tune Motor Control - I/F Control
81
Tune Motor Control - PM Control
81
Setup Non-Franklin Electric PM Motors
81
Basic Setup
81
Permanent Magnet Specific Parameters
82
Motor Specific Parameters
82
Autotune Characteristic Parameters
82
Tune Motor Control - DC Alignment
82
Tune Motor Control - I/F Control
82
Tune Motor Control - PM Control
83
Multi-Motor Configurations
83
Multi-Motor (MMC) Relay Control for Pump Applications
84
Communications
85
FE Connect for Cerus X-Drive Mobile Application
85
Setup Bluetooth Connection
85
Using the Mobile App
86
Modbus Communication
87
X-Drive Configuration for Modbus
87
Communication Parameters Setup
87
System Parameters Setup
88
Modbus Commands and Data Addresses
89
Bacnet Communication
90
X-Drive Configuration for Bacnet
90
Communication Parameters Setup
90
System Parameters Setup
90
Bacnet Device ID Setup
91
Bacnet Objects
91
Commandable Analog Value Objects
91
Status Analog Value Objects (Read Only)
91
Commandable Binary Value Objects
92
Status Binary Value Objects (Read Only)
93
Accessories
95
Optional Extension Cards
95
Extension Card Installation
97
Setup Optional Ethernet Communication Card
101
Maintenance
103
Troubleshooting
103
Diagnostic Fault Codes
103
Fan Replacement
108
Frame a Heat Sink Fan
108
Frame B Heat Sink Fan
108
Frame B and C Capacitor Fan
109
Frame C Heat Sink Fan
109
Frame D Heat Sink Fan
110
Frame D Capacitor Fan
110
Frame E Heat Sink Fan
111
Frame E Capacitor Fan
111
Frame F Heat Sink Fan
112
Frame F Capacitor Fan
112
Frame G Heat Sink Fan
113
Frame H Heat Sink Fan
114
Parameter Reference Tables
115
Parameter Descriptions > SET Menu
115
Parameter Descriptions > VFD Menu
119
Parameter Descriptions > I/O Menu
122
Parameter Descriptions > ADV Menu
128
Parameter Descriptions > PROTECTION Menu
130
Parameter Descriptions > COMM Menu
132
Parameter Descriptions > PLC Menu
134
Parameter Descriptions > Option Menu
136
Parameter Descriptions > ADV2 Menu
138
Parameter Descriptions > Motor Menu
139
Specifications
141
Common Specifications
141
Class 1~125HP (0.75~90Kw)
142
Class 1~75HP (5.5~55Kw)
143
Class 100~675HP (75~500Kw)
144
Class 1~150HP (1.5~175Kw)
145
Class 150~700HP (160~522Kw)
146
De-Rating Charts
147
Carrier Frequency De-Rating
147
230 V / 460 V Induction Motor with VF or SVC Control
147
230 V / 460 V Permanent Magnet Motor with SVC Control
147
575 V / 690 V Induction Motor with VF or SVC Control
148
Ambient Temperature De-Rating
149
Altitude De-Rating
149
Replacement Components List
150
Applicable Standards
152
Glossary
153
Standard Limited Warranty
155
Franklin Electric Cerus X-Drive Quick Start Manual (21 pages)
Brand:
Franklin Electric
| Category:
DC Drives
| Size: 1.6 MB
Table of Contents
Physical Installation
2
Environmental Requirements
2
Mounting the Drive
3
Electrical Installation
3
Wiring Guidelines
3
Branch Circuit Protection
4
Wire Sizing
4
Power Wiring Connections
5
Control Circuit Connections
6
Terminal Identification
6
Example Configurations
7
Drive Configuration
10
Using the Keypad
10
Basic Operation
13
Franklin Electric Cerus X-Drive Quick Start Manual (17 pages)
Variable Frequency Drive
Brand:
Franklin Electric
| Category:
DC Drives
| Size: 1.46 MB
Table of Contents
Mounting the Drive
2
Electrical Installation
2
Wiring Guidelines
2
Branch Circuit Protection
3
Wire Sizing
3
Power Wiring Connections
4
Control Circuit Connections
5
Drive Configuration
9
Operation
11
Safety Information
16
Related Products
Franklin Electric CXD-091A-4V
Franklin Electric CXD-110A-4V
Franklin Electric CXD-930A-4V
Franklin Electric CELLGUARD
Franklin Electric CELLTRON ADVANTAGE DIGITAL
Franklin Electric Celltron UNITE
Franklin Electric CELLGUARD GEN III
Franklin Electric CELLGUARD CGBC WD Series
Franklin Electric CERUS X-DRIVE CXD-010A-2V
Franklin Electric 5870202003
Franklin Electric Categories
Water Pump
Controller
DC Drives
Engine
Measuring Instruments
More Franklin Electric Manuals