beautypg.com
Manuals
Brands
Honeywell Manuals
Security System
Ademco VISTA-50P
Honeywell Ademco VISTA-50P Manuals
Manuals and User Guides for Honeywell Ademco VISTA-50P. We have
3
Honeywell Ademco VISTA-50P manuals available for free PDF download: Installation And Setup Manual, User Manual, Programming Manual
Honeywell Ademco VISTA-50P Installation And Setup Manual (112 pages)
Ademco Vista Series
Brand:
Honeywell
| Category:
Security System
| Size: 0.92 MB
Table of Contents
Table of Contents
3
List of Figures
5
Conventions Used in this Manual
6
SECTION 1: General Description
7
About the VISTA-50P/VISTA-50PUL
7
Features
7
SECTION 2: Partitioning
9
Theory of Partitioning
9
Setting-Up a Partitioned System
9
Common Lobby Logic
9
Master Keypad Setup and Operation
11
SECTION 3: Installing the Control
13
Mounting the Control Cabinet
13
Installing the Cabinet Lock
13
Grade a Mercantile Premises Listing Guidelines
13
Figure 3-1: Installing the Lock
13
Grade a Mercantile Safe and Vault Listing Guidelines
14
Installing the Control's Circuit Board
14
Figure 3-2: Cabinet Attack Resistance Considerations
14
Figure 3-3: Mounting the PC Board
14
Installing the Keypads
15
Figure 3-4: Keypad Connections to Control Panel
15
Figure 3-5: Using a Supplementary Power Supply
15
Installing External Sounders
16
Figure 3-6: Wiring Polarized Fire Devices
17
Figure 3-7: Wiring Nonpolarized Burglary Devices
17
Telephone Line Connections
18
Wiring Burglary, Panic, and Smoke Detector Devices to Zones 1-9
18
Figure 3-8: Telephone Line Connections
18
Figure 3-9: Wiring Connections for Zones 1-9
19
Figure 3-11: 4-Wire Smoke Detectors
20
Figure 3-12: Wiring a 333PRM to the Control
21
Figure 3-13: Wiring a 333PRM Using a 4204
21
Figure 3-14: Wiring a 333PRM Using a 4204 and a Power Supply
22
Installing RPM Devices
23
Figure 3-16: Polling Loop Connections to the VISTA-50P/VISTA-50PUL
24
Figure 3-17: Polling Loop Connections Using One 4297 Extender Module
24
Wireless Zone Expansion
25
Figure 3-18: Polling Loop Connections Using Multiple Extender Modules
25
Figure 3-19: Installing the 5881ENHC with Tamper Protection
26
Figure 3-20: 5881 RF Receiver (Cover Removed)
27
House ID Sniffer Mode
27
Installing Output Devices
29
Figure 3-21: 4204 Relay Module
29
Installing the Ground Start Module
30
Installing a Remote Keyswitch
30
Figure 3-22: Ground Start Module Connections
30
Remote Keypad Sounder
31
Figure 3-23: Remote Keyswitch Wiring
31
Figure 3-24: Remote Keypad Sounder Wiring
31
Long Range Radio Connected to the J7 Triggers
32
Installing a 4100SM
32
Installing the 4285/4286 VIP Module
32
Figure 3-25: 4100SM Using a Serial Printer
32
Installing the Audio Alarm Verification Module
34
Figure 3-26: VIP Module Connections
34
Figure 3-27: UVS Connections to the Control Panel
35
Connecting the Transformer
36
Figure 3-28: 1321 Transformer and Battery Connections
36
Figure 3-29: 1361X10 Transformer Connections
36
Panel Earth Ground Connections
37
Determining the Control's Power Supply Load
37
Determining the Size of the Standby Battery
38
SECTION 4: Programming
41
Program Modes
41
Entering and Exiting Programming Mode
41
Data Field Programming Mode
41
#93 Menu Mode Programming
42
Programming System-Wide Data Fields
42
Programming Partition-Specific Data Fields
42
Index
43
Zone Number Designations
44
Zone Response Type Definitions
45
Zone Input Type Definitions
46
Programming for 4100SM
47
Programming for Access Control
47
SECTION 5: Data Field Descriptions
49
About Data Field Programming
49
Programming Data Fields
49
Ignore Expansion Zone Tamper
51
Intelligent Test Report
51
Test Report Interval
51
Power-Up in Previous State
51
Touchtone or Rotary Dial
51
Pabx Access Code
51
Primary Phone Number
52
Secondary Phone Number
52
Download Phone Number
52
Download ID Number
52
Download Command Enables
52
Prevent Zone XX Bypass
52
Normally Closed or Eolr (Zones)
52
Dial Tone Pause
52
Dial Tone Detection
53
Ring Detection Count
53
Low Speed Format (Secondary)
53
Sescoa/Radionics Select
53
First Test Report Time
56
Restore Report Timing
56
Lobby Partition
57
Exit Error Logic Enable
57
Exit Delay Reset
57
Rf Transmitter Check-In Interval
59
Touchtone with Rotary Backup
59
Call Waiting Defeat
60
Wireless Keypad Tamper Detect
60
Chime on External Siren
60
Wireless Keypad Assignment
60
Send Cancel if Alarm + off
60
Disable Download Callback
60
Zone 5 Audio Alarm Verification
61
Event Log Types
61
Event Log Printer On-Line Mode
61
Printer Baud Rate
61
Relay Timeout XXX Minutes
61
Relay Timeout Yyy Seconds
61
Number of Partitions
61
Enable Goto for this Partition
63
Use Partition Descriptor
63
Enable J7 Triggers for Partition
63
Supervision Pulses for Lrr
63
SECTION 6: Scheduling Options
65
Extend Closing Window
65
Force Arm
65
Disarm Delay
65
Restrict Disarming
65
Time Window Definitions
66
Exception Reports
66
Open/Close Schedules Definitions
67
Holiday Schedule
67
Open/Close Reports by Exception
67
Temporary Schedule
67
Scheduling Menu Mode
68
Time Windows
69
Daily Open/Close Schedules
70
Open/Close Schedule Programming
70
Holiday Schedules
70
Time-Driven Events
71
Holiday Schedule Programming
71
Limitation of Access Schedules
74
Limitation of Access Schedules Programming
74
Temporary Schedules
75
User Scheduling Menu Mode
76
Temporary Schedules Programming
76
SECTION 7: Downloading Primer
79
General Information
79
Getting On-Line with a Control Panel
80
On-Line Control Functions
80
Direct-Wire Downloading
81
Telco Handoff
81
Figure 7-1: Direct-Wire Downloading Connections
81
SECTION 8: Setting the Real-Time Clock
83
General Information
83
Setting the Time and Date
83
SECTION 9: User Access Codes
85
General Information
85
User Codes & Levels of Authority
85
Multiple Partition Access
86
Adding a Master, Manager, or Operator Code
87
Changing a Master, Manager, or Operator Code
88
Adding an RF Key to an Existing User
88
Deleting a Master, Manager, or Operator Code
88
Exiting the User Edit Mode
88
SECTION 10: Testing the System
89
Battery Test
89
Dialer Test
89
Burglary Walk-Test (Code + [5] TEST)
89
Armed Burglary System Test
89
Testing Wireless Transmitters
90
Transmitter ID Sniffer Mode
90
Trouble Conditions
91
To the Installer
91
APPENDIX A: Regulatory Agency Statements
93
UL Installation Requirements
93
UL609 Grade a Local Mercantile Premises/Local Mercantile Safe & Vault
93
UL365 Police Station Connected Burglar Alarm
93
UL611/UL1610 Central Station Burglary Alarm
94
California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements
94
APPENDIX B: Summary of System Commands
97
APPENDIX C: Specifications
99
APPENDIX D: Contact ID Event Codes
101
Table of Contact ID Event Codes
101
Index
103
The Limitations of this Alarm System
108
Limited Warranty
109
Honeywell Ademco VISTA-50P User Manual (72 pages)
Ademco Vista Series Commercial Burglary Partitioned Security System with Scheduling
Brand:
Honeywell
| Category:
Security System
| Size: 0.34 MB
Table of Contents
Table of Contents
3
System Overview
5
General
5
A Partitioned System
5
Zones
5
Fire Protection
6
Burglary Protection
6
Alarms
6
Memory of Alarm
6
Speed Key (Macros)
7
Using Schedules
7
Device Timers
7
To Access Another Partition (GOTO Command)
7
Master Keypad Operation
8
Self-Help Feature
8
Phone Access & Voice Response Capability
8
About the Keypads
9
General
9
The Alpha Keypad
9
Functions of the Keypad
10
Entry/Exit Delays
13
General Information
13
Security Codes & Authority Levels
14
General Information
14
Duress Code
14
Quick Arming
14
Authority Levels
15
General Rules on Authority Levels and Changes
16
To Exit User Edit Mode
16
To Add a User
17
To Change a User's Code
19
To Delete a User
19
Accessing Other Partitions
20
To Access Another Partition
20
Global Arming
20
Master Keypad Operation
22
Common Lobby Operation
23
How User Codes Affect the Common Lobby
24
Checking for Open Zones
25
Using the ✳ READY Key
25
Displaying All Zone Descriptors
26
Using the ✳ READY Key
26
Bypassing Protection Zones
27
Using the 6 BYPASS Key
27
Quick Bypass
28
Displaying Bypassed Zones
28
Arming Perimeter Only
29
Using the 3 STAY Key
29
Arming Perimeter Only
30
Using the 7 INSTANT Key
30
Arming All Protection
31
Using the 2 AWAY Key
31
Arming All Protection
32
Using the 4 MAXIMUM Key
32
Disarming and Silencing Alarms
33
Using the 1 off Key
33
Memory of Alarm
33
Using the Keyswitch
34
General
34
Arming
34
Disarming
34
Chime Mode
35
Using the 9 Key
35
Viewing Alarm Company Messages
36
General Information
36
Panic Keys
37
Using Panic Keys
37
Speed Key (Macros)
38
General Information
38
Defining
38
Executing
39
Access Door Control
40
General Information
40
Executing
40
Using #70 Relay Menu Mode
41
General Information
41
Using Schedules
42
Delaying the Closing Time
42
Temporary Open/Close Schedules
42
Programming Temporary Schedules
43
Programming Device Timers
45
General Information
45
Event Log Procedures
47
General Information
47
To Display the Event Log
47
Testing the System
49
(To be Conducted Weekly)
49
Using the 5 TEST Key
49
Testing Your System
49
Fire Alarm System
50
In Case of Fire Alarm
50
Silencing a Fire Alarm
50
Typical Trouble Displays
51
Power Failure
52
Non-Alpha Keypad Displays
52
Recommendations for Smoke and Heat Detectors
53
Recommendations for Proper Intrusion Protection
54
Emergency Evacuation
55
Maintaining Your System
56
Taking Care of Your System
56
Replacing Batteries in Wireless Sensors
56
Silencing Low Battery Warning Tones at the Keypad
57
Routine Care
57
Quick Guide to System Functions
58
Summary of Audible Notification
60
Index
65
Honeywell Ademco VISTA-50P Programming Manual (48 pages)
Ademco Vista Series Commercial Bulgary Partitioned Security System With Scheduling
Brand:
Honeywell
| Category:
Security System
| Size: 0.42 MB
Table of Contents
Table of Contents
2
Recommended Programming Procedure
3
Program System-Wide (Global) Data Fields
3
Program Field Index
4
VISTA-50P/VISTA-50PUL Programming Form
5
Partition-Specific
5
Menu Mode
5
Menu Mode
6
Menu
7
Menu Mode
7
Menu Mode
8
System-Wide
9
Partition-Specific Fields
10
Programming with #93 Menu Mode
12
Zone Programming
13
Communications
13
5800 Series Transmitters Loop Designations
15
Expert Mode Zone Programming
16
Menu Mode
16
Alpha Descriptors Programming
20
Menu Mode
20
Alpha Descriptor Vocabulary
23
Device Programming
24
Menu Mode
24
Relay Programming
25
Communications
26
Relay Voice Descriptors
28
Substitutes Vocabulary
29
Custom Word Substitutes for VIP Module Annunciation
30
System Layout Worksheets
31
Communications
31
Relay Devices Worksheets
39
Communications
40
Scheduling Menu Prompts
41
Scheduling Worksheets
42
VISTA-50P/VISTA-50PUL Summary of Connections Diagram
47
Related Products
Honeywell Ademco VISTA-50PUL
Honeywell VISTA - 15P Series
Honeywell Ademco VISTA-20P
Honeywell VISTA-32FBPT
Honeywell Ademco Vista-12D
Honeywell VISTA-20PS Series
Honeywell ADEMCO Vista-12 Series
Honeywell VISTA-128BPEN
Honeywell VISTA-128FBPN
Honeywell VISTA-15P
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals