beautypg.com
Manuals
Brands
HP Manuals
Server
ProLiant DL560
HP ProLiant DL560 Manuals
Manuals and User Guides for HP ProLiant DL560. We have
9
HP ProLiant DL560 manuals available for free PDF download: Troubleshooting Manual, User Manual, Specification, Quickspecs, Implementation Manual, Technology Brief, Introduction Manual
HP ProLiant DL560 Troubleshooting Manual (152 pages)
Hewlett-Packard ProLiant Servers Troubleshooting Guide
Brand:
HP
| Category:
Server
| Size: 1.98 MB
Table of Contents
Troubleshooting Guide
1
Table of Contents
3
Introduction
10
What's New
10
Revision History
10
375445-Xx4 (May 2006)
10
375445-Xx3 (September 2005)
10
The Fifth Edition of the HP Proliant Servers Troubleshooting Guide, Part Number 375445-Xx5, Includes the
10
Getting Started
11
Pre-Diagnostic Steps
12
Important Safety Information
12
Symbols on Equipment
12
Symptom Information
14
Prepare the Server for Diagnosis
14
Common Problem Resolution
15
Loose Connections
15
Service Notifications
15
Updating Firmware
15
Hard Drive Guidelines
16
SAS and SATA Hard Drive Guidelines
16
SCSI Hard Drive Guidelines
16
Hot-Plug SCSI Hard Drive LED Combinations
16
SAS and SATA Hard Drive LED Combinations
17
Diagnostic Flowcharts
19
Troubleshooting Flowcharts
19
C-Class Server Blade Fault Indications Flowchart (on
19
C-Class Server Blade POST Problems Flowchart (on
19
General Diagnosis Flowchart
20
Start Diagnosis Flowchart
20
Power-On Problems Flowchart
22
POST Problems Flowchart
26
Operating System Boot Problems Flowchart
28
Server Fault Indications Flowchart
29
Hardware Problems
32
Procedures for All Proliant Servers
32
Power Problems
32
Power Source Problems
32
Power Supply Problems
32
UPS Problems
33
General Hardware Problems
33
Problems with New Hardware
33
Unknown Problem
34
Third-Party Device Problems
35
Internal System Problems
35
CD-ROM and DVD Drive Problems
35
Diskette Drive Problems
36
Tape Drive Problems
37
Hard Drive Problems
39
Fan Problems
40
Memory Problems
41
PPM Problems
42
Processor Problems
42
System Open Circuits and Short Circuits
43
External Device Problems
43
Video Problems
43
Mouse and Keyboard Problems
44
Audio Problems
45
Printer Problems
45
Local I/O Cable Problems
45
Modem Problems
45
Network Controller Problems
47
Software Problems
49
Operating System Problems and Resolutions
49
Operating System Problems
49
Operating System Updates
50
Restoring to a Backed-Up Version
51
When to Reconfigure or Reload Software
51
Linux Operating Systems
52
Application Software Problems
52
Software Locks up
52
Errors Occur after a Software Setting Is Changed
52
Errors Occur after the System Software Is Changed
52
Errors Occur after an Application Is Installed
52
Remote ROM Flash Problems
52
General Remote ROM Flash Problems Are Occurring
52
Command-Line Syntax Error
53
Access Denied on Target Computer
53
Invalid or Incorrect Command-Line Parameters
53
Network Connection Fails on Remote Communication
53
Failure Occurs During ROM Flash
53
Target System Is Not Supported
53
Software Tools and Solutions
54
Configuration Tools
54
Array Configuration Utility
54
Smartstart Software
54
Smartstart Scripting Toolkit
55
HP ROM-Based Setup Utility
55
Configuring Online Spare Memory
56
Option ROM Configuration for Arrays
57
HP Proliant Essentials Rapid Deployment Pack
57
Re-Entering the Server Serial Number and Product ID
57
Management CD
58
Management Tools
58
Automatic Server Recovery
58
Rompaq Utility
58
Remote Insight Lights-Out Edition II
58
Integrated Lights-Out Technology
58
Erase Utility
59
Storageworks Library and Tape Tools
59
HP Systems Insight Manager
59
Management Agents
59
HP Proliant Essentials Virtualization Management Software
59
HP Proliant Essentials Server Migration Pack - Physical to Proliant Edition
60
HP Bladesystem Essentials Insight Control Data Center Edition
60
HP Control Tower
60
System Management Homepage
61
USB Support
61
Clustering Software
61
Diagnostic Tools
61
HP Insight Diagnostics
61
Survey Utility
62
Integrated Management Log
62
Smart Array Scsi Diagnosis Feature
62
Array Diagnostic Utility
63
Remote Support and Analysis Tools
63
HP Instant Support Enterprise Edition
63
Web-Based Enterprise Service
63
Open Services Event Manager
63
Keeping the System Current
63
Drivers
63
Version Control
64
Resource Paqs
64
Proliant Support Packs
64
Operating System Version Support
64
Softpaqs
64
Change Control and Proactive Notification
64
Care Pack
65
Firmware Maintenance
65
Types of ROM
65
System Rom
65
Methods for Updating Firmware
66
Current Firmware Versions
67
Updating Firmware
67
HP Resources for Troubleshooting
69
Online Resources
69
HP Website
69
Server Documentation
69
Service Notifications
69
Subscriber's Choice
69
Natural Language Search Assistant
69
Care Pack
69
White Papers
70
General Server Resources
70
Additional Product Information
70
Device Driver Information
70
External Cabling Information
70
Fault Tolerance, Security, Care and Maintenance, Configuration and Setup
70
Installation and Configuration Information for the Server Management System
70
Installation and Configuration Information for the Server Setup Software
70
Ilo Information
70
Key Features, Option Part Numbers
70
Management of the Server
71
Operating System Installation and Configuration Information (for Factory-Installed Operating Systems)
71
Operating System Version Support
71
Overview of Server Features and Installation Instructions
71
Power Capacity
71
Registering the Server
71
Server Configuration Information
71
Software Installation and Configuration of the Server
71
Switch Settings, LED Functions, Drive, Memory, Expansion Board and Processor Installation Instructions, and Board Layouts
71
Server and Option Specifications, Symbols, Installation Warnings, and Notices
72
Teardown Procedures, Part Numbers, Specifications
72
Technical Topics
72
Error Messages
73
ADU Error Messages
73
Introduction to ADU Error Messages
73
Accelerator Board Not Detected
73
Accelerator Error Log
73
Accelerator Parity Read Errors: X
73
Accelerator Parity Write Errors: X
74
Accelerator Status: Cache was Automatically Configured During Last Controller Reset
74
Accelerator Status: Data in the Cache was Lost
74
Accelerator Status: Dirty Data Detected Has Reached Limit
74
Accelerator Status: Dirty Data Detected
74
Accelerator Status: Excessive ECC Errors Detected in at Least One Cache Line
74
Accelerator Status: Excessive ECC Errors Detected in Multiple Cache Lines
74
Accelerator Status: Obsolete Data Detected
75
Accelerator Status: Obsolete Data was Discarded
75
Accelerator Status: Obsolete Data was Flushed (Written) to Drives
75
Accelerator Status: Permanently Disabled
75
Accelerator Status: Possible Data Loss in Cache
75
Accelerator Status: Temporarily Disabled
75
Accelerator Status: Unrecognized Status
75
Accelerator Status: Valid Data Found at Reset
76
Accelerator Status: Warranty Alert
76
Adapter/Nvram ID Mismatch
76
Array Accelerator Battery Pack X Not Fully Charged
76
Array Accelerator Battery Pack X below Reference Voltage (Recharging)
76
Board in Use by Expand Operation
76
Board Not Attached
76
Cache Has Been Disabled Because ADG Enabler Dongle Is Broken or Missing
76
Cache Has Been Disabled; Likely Caused by a Loose Pin on One of the RAM Chips
77
Configuration Signature Is Zero
77
Configuration Signature Mismatch
77
Controller Communication Failure Occurred
77
Controller Detected. NVRAM Configuration Not Present
77
Controller Firmware Needs Upgrading
77
Controller Is Located in Special "Video" Slot
77
Controller Is Not Configured
77
Controller Reported POST Error. Error Code: X
78
Controller Restarted with a Signature of Zero
78
Disable Command Issued
78
Drive (Bay) X Firmware Needs Upgrading
78
Drive (Bay) X Has Insufficient Capacity for Its Configuration
78
Drive (Bay) X Has Invalid M&P Stamp
78
Drive (Bay) X Has Loose Cable
78
Drive (Bay) X Is a Replacement Drive
79
Drive (Bay) X Is a Replacement Drive Marked OK
79
Drive (Bay) X Is Failed
79
Drive (Bay) X Is Undergoing Drive Recovery
79
Drive (Bay) X Upload Code Not Readable
79
Drive (Bay) X was Inadvertently Replaced
79
Drive Monitoring Features Are Unobtainable
80
Drive Monitoring Is NOT Enabled for SCSI Port X Drive ID y
80
Drive Time-Out Occurred on Physical Drive Bay X
80
Drive X Indicates Position y
80
Duplicate Write Memory Error
80
Error Occurred Reading RIS Copy from SCSI Port X Drive ID
80
FYI: Drive (Bay) X Is Third-Party Supplied
80
Identify Logical Drive Data DID Not Match with NVRAM
81
Insufficient Adapter Resources
81
Inter-Controller Link Connection Could Not be Established
81
Less than 75% Batteries at Sufficient Voltage
81
Less than 75% of Batteries at Sufficient Voltage Battery Pack X below Reference Voltage
81
Logical Drive X Failed Due to Cache Error
81
Logical Drive X Status = Failed
81
Logical Drive X Status = Interim Recovery (Volume Functional, but Not Fault Tolerant)
82
Logical Drive X Status = Loose Cable Detected
82
Logical Drive X Status = Overheated
82
Logical Drive X Status = Overheating
82
Logical Drive X Status = Recovering (Rebuilding Data on a Replaced Drive)
82
Logical Drive X Status = Wrong Drive Replaced
83
Loose Cable Detected - Logical Drives May be Marked FAILED until Corrected
83
Mirror Data Miscompare
83
No Configuration for Array Accelerator Board
83
One or more Drives Is Unable to Support Redundant Controller Operation
83
Other Controller Indicates Different Hardware Model
83
Other Controller Indicates Different Firmware Version
84
Other Controller Indicates Different Cache Size
84
Processor Reduced Power Mode Enabled in RBSU
84
Processor Not Started (Processor Stalled)
84
Processor Not Started (Stepping Does Not Match)
84
Processor Not Started (Unsupported Processor Stepping)
84
Processor Not Supported (Unsupported Core Speed)
84
RIS Copies between Drives Do Not Match
84
SCSI Port X Drive ID y Failed - REPLACE (Failure Message)
85
SCSI Port X, Drive ID y Firmware Needs Upgrading
85
SCSI Port X, Drive ID y Has Exceeded the Following Threshold(S)
85
SCSI Port X, Drive ID y Is Not Stamped for Monitoring
85
SCSI Port X, Drive ID y May Have a Loose Connection
85
SCSI Port X, Drive ID y RIS Copies Within this Drive Do Not Match
85
SCSI Port X, Drive ID y
85
Performance Data
85
Performance Data
86
SCSI Port X, Drive ID y was Replaced on a Good Volume: (Failure Message)
86
Set Configuration Command Issued
86
Soft Firmware Upgrade Required
86
Storage Enclosure on SCSI Bus X Has a Cabling Error (Bus Disabled)
86
Storage Enclosure on SCSI Bus X Indicated a Door Alert
86
Storage Enclosure on SCSI Bus X Indicated a Power Supply Failure
86
Storage Enclosure on SCSI Bus X Indicated an Overheated Condition
87
Storage Enclosure on SCSI Bus X Is Unsupported with Its Current Firmware Version
87
Storage Enclosure on SCSI Bus X Indicated that the Fan Failed
87
Storage Enclosure on SCSI Bus X Indicated that the Fan Is Degraded
87
Storage Enclosure on SCSI Bus X Indicated that the Fan Module Is Unplugged
87
Storage Enclosure on SCSI Bus X - Wide SCSI Transfer Failed
87
Swapped Cables or Configuration Error Detected. a Configured Array of Drives
88
Swapped Cables or Configuration Error Detected. a Drive Rearrangement
88
Swapped Cables or Configuration Error Detected. an Unsupported Drive Arrangement was Attempted
88
Swapped Cables or Configuration Error Detected. the Cables Appear to be Interchanged
88
Swapped Cables or Configuration Error Detected. the Configuration Information on the Attached Drives
89
Swapped Cables or Configuration Error Detected. the Maximum Logical Volume Count X
89
System Board Is Unable to Identify Which Slots the Controllers Are in
89
The Redundant Controllers Installed Are Not the same Model
89
This Controller Can See the Drives but the Other Controller Can't
90
This Controller Can't See the Drives but the Other Controller Can
90
Unable to Communicate with Drive on SCSI Port X, Drive ID y
90
Unable to Retrieve Identify Controller Data. Controller May be Disabled or Failed
90
Unknown Disable Code
90
Unrecoverable Read Error
90
Unsupported Processor Configuration (Processor Required in Slot #1)
91
Warning Bit Detected
91
WARNING - Drive Write Cache Is Enabled on X
91
WARNING - Mixed Feature Processors Were Detected
91
WARNING - Resetting Corrupted CMOS
91
WARNING - Resetting Corrupted NVRAM
91
WARNING - Resetting Corrupted System Environment
91
WARNING - Restoring Default Configurations as Requested
91
WARNING: Storage Enclosure on SCSI Bus X Indicated It Is Operating in Single Ended Mode
92
Write Memory Error
92
Wrong Accelerator
92
POST Error Messages and Beep Codes
92
Introduction to POST Error Messages
92
Non-Numeric Messages or Beeps Only
93
Power Faults/Supply Solutions
98
Redundant ROM Detected/Errors
98
100 Series
101
Rom Error
101
Memory Error
103
Series
103
300 Series
106
400 Series
107
600 Series
108
1100 Series
109
1700 Series
112
1779-Slot-X Drive Array Replacement Drive Detected
119
1783-Intelligent Drive Array Controller Failure
119
1783-Slot-X Drive Array Controller Failure
119
1784-Slot X Drive Array Drive Failure
119
1785-Slot X Drive Array Not Configured
120
1786-Slot 1 Drive Array Recovery Needed
120
1786-Slot 1 Drive Array Recovery Needed
121
1787-Drive-Array Operating in Interim Recovery Mode
121
Event List Error Messages
124
A CPU Power Module (System Board, Socket X)
124
ASR Lockup Detected: Cause
124
Introduction to Event List Error Messages
124
Automatic Operating System Shutdown Initiated Due to Fan Failure
125
Automatic Operating System Shutdown Initiated Due to Overheat Condition
125
Blue Screen Trap: Cause [NT]
125
Corrected Memory Error Threshold Passed (Slot X, Memory Module Y)
125
EISA Expansion Bus Master Timeout (Slot X)
125
PCI Bus Error (Slot X, Bus Y, Device Z, Function X)
125
Processor Correctable Error Threshold Passed (Slot X, Socket Y)
125
Processor Uncorrectable Internal Error (Slot X, Socket Y)
125
Real-Time Clock Battery Failing
126
System AC Power Overload (Power Supply X)
126
System AC Power Problem (Power Supply X)
126
System Fan Failure (Fan X, Location)
126
System Fans Not Redundant
126
System Overheating (Zone X, Location)
126
System Power Supplies Not Redundant
126
Unrecoverable Host Bus Data Parity Error
126
HP Bladesystem Infrastructure Error Codes
127
Server Blade Error Codes
127
Server Blade Management Module Error Codes
127
Uncorrectable Memory Error (Slot X, Memory Module Y)
127
Power Management Module Error Codes
130
Port 85 Codes and Ilo Messages
131
Processor-Related Port 85 Codes
131
Troubleshooting the System Using Port 85 Codes
131
Memory-Related Port 85 Codes
132
Expansion Board-Related Port 85 Codes
133
Miscellaneous Port 85 Codes
133
Message ID: 4137
134
Message ID: 4140
134
Message ID: 4141
134
Message ID: 4169
134
Message ID: 4190
134
Windows Event Log Processor Error Codes
134
Insight Diagnostics Processor Error Codes
135
Msg_Cpu_Rr_1
135
Msg_Cpu_Rr_2
135
Msg_Cpu_Rr_3
135
Msg_Cpu_Rr_5
135
Msg_Cpu_Rr_6
135
Msg_Cpu_Rr_10
136
Msg_Cpu_Rr_11
136
Msg_Cpu_Rr_12
136
Msg_Cpu_Rr_13
136
Msg_Cpu_Rr_14
136
Msg_Cpu_Rr_15
136
Msg_Cpu_Rr_16
136
Msg_Cpu_Rr_7
136
Msg_Cpu_Rr_8
136
Msg_Cpu_Rr_9
136
Msg_Cpu_Rr_17
137
Contacting HP
138
Contacting HP Technical Support or an Authorized Reseller
138
Customer Self Repair
138
Server Information You Need
139
Operating System Information You Need
139
Microsoft Operating Systems
139
Linux Operating Systems
140
Novell Netware Operating Systems
141
SCO Operating Systems
141
IBM OS/2 Operating Systems
142
Sun Solaris Operating Systems
142
Acronyms and Abbreviations
144
Index
148
HP ProLiant DL560 User Manual (136 pages)
HP ProLiant DL560 Server User Guide
Brand:
HP
| Category:
Server
| Size: 4.6 MB
Table of Contents
Table of Contents
3
Server Component Identification
7
Front Panel Components
8
Front Panel Leds and Buttons
9
Rear Panel Components
11
Rear Panel Leds and Buttons
12
System Board Components
13
NMI Switch
14
Chassis ID Switch
15
DIMM Slots
15
System Maintenance Switch
16
System Board Leds
17
System Leds and Internal Health LED Combinations
19
SCSI Backplane Components
22
Hot-Plug SCSI Hard Drive Leds
23
Hot-Plug SCSI Hard Drive LED Combinations
24
PCI Riser Cage LED
25
Remote Management Connector
25
Hot-Plug Fans
26
Hot-Plug Fan LED
27
Server Operations
29
Powering up the Server
29
Powering down the Server
29
In this Section Powering up the Server
29
Extending the Server from the Rack
30
Removing the Access Panel
32
Installing the Access Panel
32
Removing the PCI Riser Cage
32
Installing the PCI Riser Cage
33
Removing the Power Module
34
Installing the Power Module
36
Server Setup
37
Optional Installation Services
37
In this Section Optional Installation Services
37
Rack Planning Resources
38
Optimum Environment
39
Space and Airflow Requirements
39
Temperature Requirements
40
Power Requirements
41
Electrical Grounding Requirements
42
Rack Warnings
42
Installing Hardware Options
43
Identifying the Contents of the Server Shipping Carton
43
Installing the Server into the Rack
44
Powering up and Configuring the Server
52
Installing the Operating System
53
Registering the Server
53
Hardware Options Installation
55
Processor Option
55
In this Section Processor Option
55
Memory Options
59
Online Spare Memory Configuration
60
DIMM Installation Guidelines
60
Installing Dimms
61
Hot-Plug SCSI Hard Drive Options
62
Removing a Hard Drive Blank
63
Removing a Hot-Plug SCSI Hard Drive
63
Installing a Hot-Plug SCSI Hard Drive
64
Hot-Plug Tape Drive Option
65
Battery-Backed Write Cache Enabler Option
66
Redundant Hot-Plug Fan Option
68
Installation Requirements
70
Installing Redundant Hot Plug Fans
70
Redundant Hot-Plug AC Power Supply Option
73
Expansion Board Options
75
Server Cabling
79
Power Button and Drive Cabling
79
Internal Power Cabling
80
RILOE II Cabling
80
Server Configuration and Utilities
83
ROM-Based Setup Utility
83
In this Section ROM-Based Setup Utility
83
Auto-Configuration Process
84
Using RBSU
84
Boot Options
85
Configuring Online Spare Memory
86
System Maintenance Menu
86
Integrated Lights-Out Technology
87
Ilo ROM-Based Setup Utility
87
Smartstart Software
88
Smartstart Autorun Menu
89
Smartstart Scripting Toolkit
89
Enterprise Diagnostics LX32 Utility
90
Proliant Essentials Rapid Deployment Pack
90
Drivers
90
USB Support
91
Redundant ROM Support
91
Safety and Security Benefits
92
Access to Redundant ROM Settings
92
Rompaq Utility
93
System Online ROM Flash Component Utility
93
Option ROM Configuration for Arrays
94
Automatic Server Recovery-2
94
Management Agents
95
Insight Manager 7
95
Survey Utility
96
Integrated Management Log
96
Server Specific Troubleshooting
99
Minimum Hardware Configuration
99
In this Section Minimum Hardware Configuration
99
Server Error Messages
100
When the Server Does Not Boot
100
Diagnostic Steps
102
Is the System Power LED Amber
103
Is the System Power LED Green
104
Is the External Health LED Green
104
Is the Internal Health LED Green
105
Is the Monitor Displaying Information
106
Problems after Initial Boot
106
System Cannot Load Smartstart
107
Smartstart Fails During Installation
107
Smartstart Cannot Load Operating System
108
Rompaq Disaster Recovery
108
Other Information Resources
109
Battery Replacement
111
Regulatory Compliance Notices
113
Regulatory Compliance Identification Numbers
113
Federal Communications Commission Notice
114
FCC Rating Label
114
Class a Equipment
114
Class B Equipment
115
Declaration of Conformity for Products Marked with the FCC Logo, United States Only
115
Modifications
116
Cables
116
Mouse Compliance Statement
116
Canadian Notice
116
European Union Notice
117
Japanese Notice
118
Taiwanese Notice
118
Laser Device Notices
119
Laser Safety Warnings
119
Compliance with CDRH Regulations
119
Compliance with International Regulations
119
Laser Product Label
120
Laser Information
120
Battery Replacement Notice
121
Electrostatic Discharge
123
Preventing Electrostatic Discharge
123
Grounding Methods to Prevent Electrostatic Discharge
124
Server Specifications
125
Server Dimensions and Weight
125
Power Specifications
125
Environmental Specifications
126
Technical Support
127
Related Documents
127
Telephone Numbers
127
Acronyms and Abbreviations
129
Index
133
HP ProLiant DL560 User Manual (41 pages)
HP Insight Management WBEM Providers for Windows Server 2003 and Windows Server 2008 User Guide
Brand:
HP
| Category:
Software
| Size: 1.3 MB
Table of Contents
User Guide
1
Table of Contents
3
Introduction
5
Overview
5
Windows Management Instrumentation
5
Installing the HP Insight Providers
6
Insight Providers Smart Components
6
Installing the Insight Providers with the PSP
6
Installing the Insight Providers as Part of a Smartstart Assisted Path Installation
7
Installing the Insight Providers Using HP SIM
8
Installing the Insight Providers Smart Component
9
Security Requirements for the Insight Providers
10
SNMP Agent Compatibility
11
Uninstalling SNMP-Based HP Insight Management Agents
12
Introduction
12
Uninstalling HP Insight Management Agents on a Single Local Server
12
Uninstalling HP Insight Management Agents on a Single Remote Server
12
Uninstalling HP Insight Management Agents on Multiple Remote Servers Using HP SIM
13
Scripting Commands for Uninstalling HP Insight Management Agents
14
Scripting Commands for HP Insight Management Agents 6.30 through 7.60
14
Scripting Commands for HP Insight Management Agents 7.70 or Later
15
Using the SMH with the Insight Providers
16
Introduction to SMH
16
Change Data Source
16
Auto Refresh
16
Threshold Settings
16
Data Collection
17
Security
18
Security Concerns
18
Implementation
18
Best Practices
18
Configuring Insight Provider Security for a User Account Using HP SIM Configure and Repair Agents
19
Configuring Insight Provider Security Using the Windows Command Line
20
Windows Server 2008 Firewall Configuration
22
Firewall Configuration Introduction
22
Firewall Configuration
22
Insight Providers Architecture
24
Architecture Overview
24
Data Model
25
Microsoft Visual Basic Scripting Edition Examples
28
Insight Providers Usage
31
Additional Documentation
32
Scripting
33
Scripting Examples
33
WMIC Example
33
Scripting References
33
Support Information
34
Operating System Support
34
Hardware Support
35
HP Driver and Support Software Prerequisites
35
Technical Support
36
Reference Documentation
36
HP Contact Information
36
Acronyms and Abbreviations
37
Index
40
HP ProLiant DL560 Implementation Manual (35 pages)
Implementing Microsoft Windows 2000 with Service Pack 4 on ProLiant servers
Brand:
HP
| Category:
Server
| Size: 0.47 MB
Table of Contents
Table of Contents
1
Abstract
3
Introduction
3
Planning Considerations
3
Installation Considerations
4
Upgrade/Migration Considerations
4
Supported Server Platforms
5
Supported Software
9
Supported Management Options and Agents
10
Supported Storage Options
11
Supported Network Interface Controllers (Nics)
13
Support Video
16
Hardware System Requirements
16
Cluster Configurations
17
System Roms and Option Roms for Microsoft Windows 2000
18
Server Setup
18
Storage Array Configuration
18
Additional Components
18
Support Software
19
Installation
19
Before Beginning
19
Smartstart Configuration
20
Installation Steps
20
Features
21
Management Agents
22
Remote Insight Lights-Out Edition Management
22
Integrated Lights-Out Remote Management
22
HP Proliant Essentials Workload Management Pack
23
Advanced Memory Protection
23
Online Spare Memory
23
Hot Plug Mirrored Memory
23
Hot Plug RAID Memory
23
Wake on LAN (WOL)
23
PCI Hot Plug
24
Pre-Boot Execution Environment (PXE)
24
Teamed Nics
25
Troubleshooting
26
Installation Issues and Solutions for Windows 2000
27
Feature Implementation
30
Conclusion
33
Appendix A HP Proliant Server Features
34
For more Information
35
Call to Action
35
HP ProLiant DL560 Specification (53 pages)
HP ProLiant DL560 Generation8 (Gen8)
Brand:
HP
| Category:
Server
| Size: 1.83 MB
Table of Contents
Standard Features
2
Virtualization Software
7
Warranty
10
Optional Features
11
Service and Support
14
Pre-Configured Models
17
Base Models
18
Configuration Information - Factory Integrated Models
20
Core Options
24
Additional Options
29
Drive Support
48
Technical Specifications
49
HP ProLiant DL560 Technology Brief (19 pages)
Brand:
HP
| Category:
Server
| Size: 0.69 MB
Table of Contents
Table of Contents
1
Abstract
3
Introduction
3
System Architecture
3
Processor Subsystem
5
400-Mhz Front Side Bus
6
Netburst Microarchitecture
6
Hyper-Threading Technology
7
Multilevel Cache System
8
Memory Subsystem
9
Advanced Memory Protection
10
2-Way Interleaved Memory
10
I/O Subsystem
10
Storage Subsystem
11
Power and Cooling
11
Racking Technology
12
Hardware Reusability
13
Deployment, Management, and Troubleshooting Technologies
13
Deployment Technologies
13
Smartstart
13
Smartstart Scripting Toolkit
14
Rapid Deployment Pack
14
Management Technologies
14
Sensors and Indicators
15
Insight Manager 7
15
Lights-Out Technology
15
Activeupdate
16
Troubleshooting Technologies
16
Survey Utility
16
Performance Management Pack
17
Consolidation Technologies
17
Resource Partitioning Manager
17
Vmware GSX and ESX Server
18
Conclusion
18
For more Information
19
Call to Action
19
HP ProLiant DL560 Quickspecs (37 pages)
Brand:
HP
| Category:
Server
| Size: 0.33 MB
Table of Contents
Standard Features
3
Drive Support
28
Power Specifications
32
System Specifications
32
Technical Specifications
33
HP ProLiant DL560 Specification (35 pages)
Brand:
HP
| Category:
Server
| Size: 0.93 MB
Table of Contents
Standard Features
3
Drive Support
27
Power Specifications
30
System Specifications
30
Technical Specifications
31
HP ProLiant DL560 Introduction Manual (13 pages)
Critical factors in intra-rack power distribution planning for high-density systems
Brand:
HP
| Category:
Server
| Size: 0.44 MB
Table of Contents
Table of Contents
1
Abstract
2
Introduction
2
Key Factors of Power Distribution in High-Density Racks
3
Power Level and Phase
3
Connector Types
4
Power Consumption
5
Space Issues
6
Segmented Power Distribution
7
Redundant Power Distribution
8
Power Circuit Monitoring
9
Other Considerations
9
Sample Power Distribution Solutions
10
Rack Configurations for Distributing Power to HP Proliant C-Class Servers
10
Rack Configurations for Distributing Power to HP Proliant DL Servers
12
Conclusion
13
For more Information
13
Call to Action
13
Related Products
HP ProLiant DL560 Gen8
HP ProLiant DL560 Generation8
HP ProLiant DL560 Generation9
HP ProLiant DL560 Gen10
HP ProLiant DL560 Gen 9
HP ProLiant DL560 Gen11
HP DL590/64
HP ProLiant DL585 G5
HP ProLiant DL585 G7
HP ProLiant DL580 G7
HP Categories
Desktop
Laptop
Server
Monitor
Switch
More HP Manuals