beautypg.com
Manuals
Brands
Keithley Manuals
Measuring Instruments
595
Keithley 595 Manuals
Manuals and User Guides for Keithley 595. We have
2
Keithley 595 manuals available for free PDF download: Instruction Manual, Quick Reference Manual
Keithley 595 Instruction Manual (239 pages)
quasistatic CV meter
Brand:
Keithley
| Category:
Measuring Instruments
| Size: 11.66 MB
Table of Contents
Safety Precautions
4
Table of Contents
9
Features
19
Manual Addenda
19
Safetyterms
19
Unpacking and Inspection
19
Accessories
20
Preparhion for Use
21
Erepacking for Shpment
20
Warranly INFORMATION
20
2-L
21
Linepower
21
Linevoltage Selection
21
Powerupprocedure
21
Powercord
21
Defaults
22
RAM and ROM Test Messages
22
General Display Messages
22
Instrument Familiarization
22
Model595Frontpanel
24
Model595Rearpanel
26
Capacitance Example
28
Cvexample
29
Measurin'g Current: Anexample
31
Example
31
Introduction
33
Section 3-Operation
33
Connections for Cment Measurements
34
DETAILED FRONT PANEL CONTROL Descrlpnons
34
Current
34
Capacitance
34
Suppress
35
ZERO Checkand Correct
35
Range a
36
A LIM.IT, V LIMIT and PRESET
37
Delay Time
37
Display Source
38
Adjust a
38
I-, Front Panel Trigger
38
Front Panel Programs
38
Calibration
39
Filter
40
Trigger
42
Display (Alpha or Numeric)
43
IEEE-488Address
43
Externaltrigger
45
Grid
45
Y Hi-Ylo
45
Rear Panels Features
45
Analog Output
46
Metercomplete
46
PART 2-MAKING CV, IV or Q/T-V Plots
47
Setting up Measurement Parameters
47
Beginningthemeasurement
48
Analog Plotting
51
Printing Results
51
Ground Loops
54
Rfi
55
Source Capacitance
55
Engineering Units Conversion
56
Bus Connections
57
Typical Controlled Systems
57
Cable Connections
58
Introduction
57
Section 4-Ieee-488 Programming
57
Shortcut to Ieee-488 Operation
57
Section 4-Ieee-488 Programming
59
Interracefunctioncodes
60
Primary Address Programming
60
Coni'roller Programmin G
61
Controller Handler Software
61
Model 595 Interface Function Codes
61
BASIC Statements Necessary to Send Bus Commands
62
Buserror
62
Interface BASIC Programming Statements
62
Number and Conflict Errors
63
General Bus Commands
64
General Bus Commands and Associated BASIC Statements
64
IFC (Interface Clear)
64
REN (Remote Enable)
64
GTL (Go to Local) and Local
65
Dcl(D&Ce Clear)
65
LLO (Local Lockout)
65
GET (Group Execute Trigger)
66
SPE, SPD (Serial Polling)
66
Sdc(Selectivedevice Clear)
66
Programming Overviav
67
Execute (X)
72
Display (D)
73
Zerocheck,Zerocorrect(Z)
76
Suppress (N)
77
Low Limit (L)
80
Voltage Source (V)
81
Step Voltage (S)
82
Delay Tie (I)
83
Capacitancemodifiers
86
Analog Output (0)
89
Triggermodeo
90
SRQ Mask (M) and Serial Poll Byte Format
91
EOI and Bus Hold-Off Modes (K)
94
Terminator(Y)
96
Status (U)
97
Digital Calibration (A)
102
Self-Test and Permanent Memory Storage U)
103
Square Wave Capacitance Measurements
104
Staircasemeasurements
104
Talk Only
105
Ieee-Plot
105
Introduction
107
Applications of the Currentfunction
107
Highresistancemeasurements
107
Section 5-Applications
107
Voltage Coefficients of High Resistances
107
Characteristics of Transistors
110
Leakage Current Measurement
113
Applications of the Capacitance Function
114
Characterizing the MOS Capacitor in Depletion and Accumulation
114
Characterizing the MOS Capacitor in Inversion
115
Equivalent Circuits of the MOS Capacitor
115
Recognizing Equilibrium Using C and Q/T
118
MOS Non-Equilibrium and Roper Use of the Corrected Capacitance Program
119
Comparison of the Feedback Charge Method with the Traditional Ramp Method
123
Bibliography of Quasistatic CV Measurements and Related Topics
127
Introduction
128
Verification Procedures
129
Inputcurrentverification
129
Section C-Performance Verification
128
Recommended Test Equipment for Performance Verification
129
Current Verification
130
Section 6-Performance Verification
130
Section B-Performance Verification
132
Q/T Verification
133
Capacitance Verification
133
Voltage Source Verification
134
Setup for Voltage Source Verification
135
Introduction
136
Cvmeasurementmethod
136
Overall Functional Description
137
D/A Converter
137
Feedback Charge Method
137
Section 7-Theory of Operation
138
Model 595 Simplified Diagram
138
Precisionstep Source
140
Output Stage
140
Output Stage Circuitry (Simplified)
141
Current Limiting for Output Stage
142
Voltage Source Reset Circuitry
143
Input Stage and Gain Stage
145
Inputandgain Stages
145
Feedbackelements
146
Past Discharge Bridge
147
Multiplexer and Buffer
150
Device Selection
153
Digital Circuitry
153
Memory Elements
153
Ieee488Bus
154
Input/Output Circuitry
154
Memory Mapping
154
Analog Outputs
155
Main Power Supply
157
Introduction
158
Line Frequency Selection
158
Line Voitage Selection
158
Section 8-Maintenance
158
Calibration
159
Fuse Replacement
159
Line Fuse Selection
159
Test Fixture Construction
159
Environmental Conditions
160
Recommended Calibration Equipment
160
Calibration Jumper and Calibration Pots
161
Section 8-Maintenance
162
Warm-Up Period
160
Calibration Sequence
163
Capacitance Offset Compensation
163
Digitalcalibration
163
Input Offset Voltage Adjustment
163
Section S-Maintenance
163
Equipment for Zero Hop Compensation
164
Current Adjustment
165
Voltage Sourcecalibration
165
Current Calibration
167
Additional Calibration Points
172
Disassembly Instruction
172
Special Handling of Sixtic Sensitive Devices
174
Troubleshooting
174
Recommended Troubleshooting Equipment
175
Recommendedtest Equipment
175
Self Diagnosticprogram
175
Lie Voltage Selection (50~&X-Iz)
176
Powersupplychecks
176
A/D~~Converter Checks
176
Voltage Source Checks
176
A/D Converter
176
Display Board, Parts List
200
Preamp Board, Parts List
204
Miscellaneous Parts, Parts List
209
Analog Outputs
217
IEEE Command Group
233
Typical Addressed Command Sequence
233
Typical Device-Dependent Command Sequence
233
Keithley 595 Quick Reference Manual (70 pages)
Quasistatic CV Meter
Brand:
Keithley
| Category:
Measuring Instruments
| Size: 1.36 MB
Table of Contents
Table of Contents
3
Condensed Specifications
8
Model 595 Features
12
Front Panel Programs
26
Measurement Connections
34
Ieee Programming
40
Programs
55
IBM PC or XT
56
Applell
58
Hp9816
62
DEC E L 11
66
Peticbm 2001
68
Related Products
Keithley 590 CV
Keithley 502
Keithley 580
Keithley 510
Keithley 5156
Keithley 148
Keithley 149
Keithley 151
Keithley 153
Keithley 172
Keithley Categories
Measuring Instruments
Multimeter
Power Supply
Test Equipment
Switch
More Keithley Manuals