beautypg.com
Manuals
Brands
OHAUS Manuals
Measuring Instruments
STARTER 3100M
OHAUS STARTER 3100M Manuals
Manuals and User Guides for OHAUS STARTER 3100M. We have
3
OHAUS STARTER 3100M manuals available for free PDF download: Instruction Manual, Service Manual
OHAUS STARTER 3100M Instruction Manual (92 pages)
Multi-parameter Bench Meter
Brand:
OHAUS
| Category:
Measuring Instruments
| Size: 2.55 MB
Table of Contents
English
3
Table of Contents
3
1 Introduction
5
Definition of Signal Warnings and Symbols
5
Safety Precautions
6
Display and Controls
7
2 Installation
9
Package Contents
9
Installing the Stand-Alone Electrode Holder
10
Installing the Power Adapter
11
Connect the Electrodes
11
Meter Stand for Adjusting View Angle
12
Attached Quick Guide
12
3 ST3100M Ph Operation
13
Setup
13
Set Temperature Unit and MTC Value
13
Selecting a Predefined Buffer Group
14
Calibration
15
Performing 1-Point Calibration
15
Performing 2-Point Calibration
16
Sample Measurement
17
Ph Measurement
17
ST3100M Conductivity Operation
17
Setup
17
Set Temperature Unit
17
Set MTC Temperature Value
17
Set Calibration Standard Point
18
Set Temperature Correction Coefficient
18
Calibration
18
Set TDS Factor
18
Selecting a Standard
19
Performing a Calibration
19
Sample Measurement
20
Conductivity Measurement
20
TDS, Salinity or Resistivity Measurement
20
5 Using the Memory
21
Storing a Reading
21
Recalling from Memory
21
6 Printing
21
Clearing the Memory
21
7 Maintenance
24
Error Message
24
Meter Maintenance
25
Self-Diagnosis
25
Recover Factory Settings
25
8 Technical Data
26
Specifications
26
Compliance
27
9 Appendix
28
Ph Buffer Groups
28
Conductivity Standards
29
Examples of Temperature Coefficients (Α-Value)
30
Conductivity to TDS Conversion Factors
30
Español
33
1 Introducción
35
Definición de Señales de Advertencia y de sí Mbolos de Advertencia
35
Precauciones de Seguridad
36
Pantalla y Controles
37
2 Instalación
39
Contenido del Paquete
39
Instalación del Soporte Autónomo para Electrodo
40
Instalación del Adaptador de Corriente
41
Conexión de Los Electrodos
41
Soporte del Medidor para Ajustar el Ángulo de Visión
42
Guí a Rápida Incluida
42
3 Uso del Ph ST3100M
43
Ajuste
43
Ingreso de la Unidad de Temperatura y del Valor MTC
43
Selección de un Grupo Tampón Predefinido
44
Calibración
45
Realización de Calibración de 1 Punto
45
Realización de Calibración de 2 Puntos
46
Medición de la Muestra
47
Medición del Ph
47
Operación de Conductividad del ST3100M
47
Ajuste
47
Ajuste de la Unidad de Temperatura
47
Ajuste del Valor de Temperatura MTC
47
Ajuste del Punto de Calibración Estándar
48
Ajuste del Coeficiente de Corrección de la Temperatura
48
Ajuste del Factor TDS
48
Calibración
49
Selección de un Estándar
49
Realización de una Calibración
49
Medición de la Muestra
50
Medición de la Conductividad
50
Almacenamiento de una Lectura
51
Borrado de la Memoria
51
Recuperación de la Memoria
51
Uso de la Memoria
51
6 Impresión
52
7 Mantenimiento
55
Mensaje de Error
55
Mantenimiento del Medidor
56
Autodiagnóstico
56
Recuperación de Los Ajustes de Fábrica
56
8 Datos Técnicos
57
Especificaciones
57
Cumplimiento
58
9 Apéndice
59
Grupos Tampones de Ph
59
Estándares de Conductividad
60
Ejemplos de Coeficientes de Temperatura (Valor Α)
61
Conductividad a Factores de Conversión TDS
61
Français
63
1 Introduction
65
Définition des Signaux D'avertissement Et de Symbole
65
Précautions de Sécurité
66
Affichage Et Contrôles
67
2 Installation
69
Contenu de L'emballage
69
Installation du Support D'électrode Indépendant
70
Installation de L'adaptateur D'alimentation
71
Connecter Les Électrodes
71
Support de Compteur Pour Réglage de L'angle de Vision
72
Guide Rapide Joint
72
3 Opération ST3100M Ph
73
Réglage
73
Régler L'unité de Température Et la Valeur MTC
73
Sélection D'un Groupe de Tampon PréDéfini
74
Calibrage
75
Effectuer 1-Point de Calibrage
75
Effectuer un Calibrage À 2 Points
76
Echantillon de Mesure
77
Mesure du Ph
77
Opération de Conductivité de ST3100M
77
Réglage
77
Régler L'unité de la Température
77
Régler la Valeur de Température MTC
77
Régler Le Point Standard de Calibrage
78
Régler Le Coefficient de Correction de la Tempé Rature
78
Régler Le Facteur TDS
78
Calibrage
78
Sélection D'une Norme
79
Effectuer un Calibrage
79
Mesure D'échantillon
80
Mesure de Conductivité
80
Mesure de TDS, Salinité Ou Résistivité
80
5 Utilisation de la Mémoire
81
Enregistrement D'une Lecture
81
Rappel À Partir de la Mémoire
81
6 Impression
81
Nettoyage de la Mémoire
81
7 Entretien
84
Message D'erreur
84
Entretien du Compteur
85
Auto Diagnostic
85
Récupérer Les Réglages D'usine
85
8 Donnees Techniques
86
Spécifications
86
Conformité
87
9 Annexes
88
Groupes de Tampon Ph
88
Normes de Conductivité
89
Exemples des Coefficients de Température (Α-Valeur)
90
OHAUS STARTER 3100M Instruction Manual (92 pages)
Multi-parameter Bench Meter
Brand:
OHAUS
| Category:
Measuring Instruments
| Size: 2.52 MB
Table of Contents
English
3
Table of Contents
3
Introduction
5
Definition of Signal Warnings and Symbols
5
Safety Precautions
6
Display and Controls
7
Installation
9
Package Contents
9
Installing the Stand-Alone Electrode Holder
10
Installing the Power Adapter
11
Connect the Electrodes
11
Meter Stand for Adjusting View Angle
12
Attached Quick Guide
12
ST3100M Ph Operation
13
Setup
13
Set Temperature Unit and MTC Value
13
Selecting a Predefined Buffer Group
14
Calibration
15
Performing 1-Point Calibration
15
Performing 2-Point Calibration
16
Ph Measurement
17
ST3100M Conductivity Operation
17
Setup
17
Set Temperature Unit
17
Set MTC Temperature Value
17
Sample Measurement
17
Set Calibration Standard Point
18
Set Temperature Correction Coefficient
18
Calibration
18
Set TDS Factor
18
Selecting a Standard
19
Performing a Calibration
19
Sample Measurement
20
Conductivity Measurement
20
TDS, Salinity or Resistivity Measurement
20
Printing
21
Clearing the Memory
21
Recalling from Memory
21
Using the Memory
21
Storing a Reading
21
Maintenance
24
Error Message
24
Meter Maintenance
25
Self-Diagnosis
25
Recover Factory Settings
25
Technical Data
26
Specifications
26
Compliance
27
Appendix
28
Ph Buffer Groups
28
Conductivity Standards
29
Examples of Temperature Coefficients (Α-Value)
30
Conductivity to TDS Conversion Factors
30
Español
33
Definición de Señales de Advertencia y de sí Mbolos de Advertencia
35
Introducción
35
Precauciones de Seguridad
36
Pantalla y Controles
37
Contenido del Paquete
39
Instalación
39
Instalación del Soporte Autónomo para Electrodo
40
Conexión de Los Electrodos
41
Instalación del Adaptador de Corriente
41
Guí a Rápida Incluida
42
Soporte del Medidor para Ajustar el Ángulo de Visión
42
Ajuste
43
Ingreso de la Unidad de Temperatura y del Valor MTC
43
Uso del Ph ST3100M
43
Selección de un Grupo Tampón Predefinido
44
Calibración
45
Realización de Calibración de 1 Punto
45
Realización de Calibración de 2 Puntos
46
Ajuste
47
Ajuste de la Unidad de Temperatura
47
Ajuste del Valor de Temperatura MTC
47
Medición de la Muestra
47
Medición del Ph
47
Operación de Conductividad del ST3100M
47
Ajuste del Coeficiente de Corrección de la Temperatura
48
Ajuste del Factor TDS
48
Ajuste del Punto de Calibración Estándar
48
Calibración
49
Realización de una Calibración
49
Selección de un Estándar
49
Medición de la Conductividad
50
Medición de la Muestra
50
Almacenamiento de una Lectura
51
Borrado de la Memoria
51
Recuperación de la Memoria
51
Uso de la Memoria
51
Impresión
52
Mantenimiento
55
Mensaje de Error
55
Autodiagnóstico
56
Mantenimiento del Medidor
56
Recuperación de Los Ajustes de Fábrica
56
Datos Técnicos
57
Especificaciones
57
Cumplimiento
58
Apéndice
59
Grupos Tampones de Ph
59
Estándares de Conductividad
60
Conductividad a Factores de Conversión TDS
61
Ejemplos de Coeficientes de Temperatura (Valor Α)
61
Français
63
Définition des Signaux D'avertissement et de Symbole
65
Introduction
65
Précautions de Sécurité
66
Affichage et Contrôles
67
Contenu de L'emballage
69
Installation
69
Installation du Support D'électrode Indépendant
70
Connecter les Électrodes
71
Installation de L'adaptateur D'alimentation
71
Guide Rapide Joint
72
Support de Compteur pour Réglage de L'angle de Vision
72
Opération ST3100M Ph
73
Réglage
73
Régler L'unité de Température et la Valeur MTC
73
Sélection D'un Groupe de Tampon PréDéfini
74
Calibrage
75
Effectuer 1-Point de Calibrage
75
Effectuer un Calibrage à 2 Points
76
Echantillon de Mesure
77
Mesure du Ph
77
Opération de Conductivité de ST3100M
77
Réglage
77
Régler L'unité de la Température
77
Régler la Valeur de Température MTC
77
Calibrage
78
Régler le Coefficient de Correction de la Tempé Rature
78
Régler le Facteur TDS
78
Régler le Point Standard de Calibrage
78
Effectuer un Calibrage
79
Sélection D'une Norme
79
Mesure D'échantillon
80
Mesure de Conductivité
80
Mesure de TDS, Salinité ou Résistivité
80
Enregistrement D'une Lecture
81
Impression
81
Nettoyage de la Mémoire
81
Rappel à Partir de la Mémoire
81
Utilisation de la Mémoire
81
Entretien
84
Message D'erreur
84
Auto Diagnostic
85
Entretien du Compteur
85
Récupérer les Réglages D'usine
85
Donnees Techniques
86
Spécifications
86
Conformité
87
Annexes
88
Groupes de Tampon Ph
88
Normes de Conductivité
89
Exemples des Coefficients de Température (Α-Valeur)
90
OHAUS STARTER 3100M Service Manual (28 pages)
Bench pH Meter
Brand:
OHAUS
| Category:
Measuring Instruments
| Size: 1.77 MB
Table of Contents
Table of Contents
3
Chapter 1 Getting Started
5
Introduction
5
Definition of Signal Words and Symbol
5
Safety Precaution
6
Service Facilities
6
Tools and Test Equipment Required
6
Specifications
7
Meter Operation Starter 2100
10
Overview of the Controls
10
Meter Operation Starter 3100
10
Overview of the Controls
14
1.10.1 Overview of the Controls
16
Chapter 2 Maintenance Procedures
18
Preventive Maintenance
18
Service Strategy
18
Opening the Meter
18
Separating the Top and Bottom Housings
18
Chapter 3 Reset to Factory Settings
20
Recover Factory Settings
20
Related Products
OHAUS STARTER 5000
OHAUS STARTER 2200
OHAUS ST300C
OHAUS ST300D
OHAUS ST400
OHAUS ST400M
OHAUS ST3100C-B
OHAUS ST2200-B
OHAUS ST300D-G
OHAUS ST300C-B
OHAUS Categories
Scales
Measuring Instruments
Laboratory Equipment
Recording Equipment
Touch Panel
More OHAUS Manuals