beautypg.com
Manuals
Brands
Panasonic Manuals
Smoke Alarm
MEW01 351
Panasonic MEW01 351 Manuals
Manuals and User Guides for Panasonic MEW01 351. We have
1
Panasonic MEW01 351 manual available for free PDF download: Planning Manual
Panasonic MEW01 351 Planning Manual (168 pages)
Fire Alarm System
Brand:
Panasonic
| Category:
Smoke Alarm
| Size: 3.3 MB
Table of Contents
Table of Contents
3
1 Introduction
10
2 Definitions / Explanations
12
Pewn Ab
12
Alarm Points
12
Smoke Detector
12
Sensor
12
Analog Detector
12
Analog (Sensor) Base (ASB)
12
Conventional Detector
12
Conventional Detector) Base (CDB)
12
Addressable
12
Conventional Zone Line Input / External Line
13
Output Unit
13
Output / Control Output
13
Short Circuit Isolator (ISO)
13
Display Unit (D.U.)
13
COM Loop
13
Control Unit / C.U. / C.I.E
13
Fire Brigade Panel (FBP)
13
Control Panel (CP)
13
System
13
Network / TLON / Lonworks / Echelon / Node / TLON Conn. Board / Channel / Backbone Net / Router / Repeater
14
Led
14
External Indicator (Ext. LED)
14
Display / LCD
14
Door Open (Door / Key Switch)
14
Site Specific Data (SSD)
15
Software (S/W) / System Program
15
3 Overview
16
The EBL512 G3 System
16
Printer
16
Expansion Boards
16
Power Supply
16
S/W Versions
17
Documents
17
Applications
17
PC Software (S/W)
17
Wing3
17
TLON Manager
18
Webg3 Iconfig Tool
18
4 Control Unit / TLON Network
19
The TLON Network
19
Single TLON Network / Redundant TLON Network
19
5 Control Units 5000 and 5001
21
Mounting Plates
23
Mounting Plate for 19" Mounting Rack, 5020
23
Mounting Plate for Inflammable Wall, 5021
23
COM Loops
24
Programmable Voltage Outputs (S0-S3)
26
Programmable Relay Outputs (R0-R1)
26
Programmable Inputs (I0-I3)
26
Relay Outputs for Routing Equipment (Tx)
27
Fire Alarm Output
27
Fault Condition Output
27
6 Expansion Boards 458X
28
Expansion Board No. (Address) Setting
29
Zones Expansion Board 4580
29
Type of Zone Line Input
30
Input States
30
Relays Expansion Board 4581
31
Inputs and Outputs Expansion Board 4583
32
I/O Matrix Board 4582
33
Generic
34
Fan Control
35
Zone Control
36
7 Printer
37
8 TLON Connection Board 1590
38
Single TLON Network
38
Redundant TLON Network
38
Network Programming
38
9 Peripheral Devices
39
COM Loop Units
39
Input Units
41
Addressable I/O Units
48
Alarm Devices (Addressable Sounders)
50
Short Circuit Isolators (Addressable)
51
Units for Hazardous (Ex) Areas
52
Other COM Loop Units
53
COM Loop Addresses for Base Station and Wireless
56
Detectors
56
Units Connected to the RS485 Interface
56
External Fire Brigade Panels
57
Alert Annunciation Units
58
External Presentation Units
59
German Fire Brigade Panels
60
Units Connected to the RS232 Interface J7
61
Web-Servers
61
Other Units
61
Alert Annunciation Controllers
61
External LED
62
Alarm Devices (Sounders, Etc.)
62
Door Release Magnets
62
Boxes
63
Duct Detector Chambers
63
10 Programmable Inputs
64
Control Unit Inputs I0 - I3 & Inputs 0 -4 on Exp. Board 4583
65
Not Supervised
65
Supervised
65
The 3361 Unit's Inputs In0 / Z & In1
65
11 Input Programming
66
Trigger Conditions
66
Logic
69
Supervised
69
12 Programmable Outputs
70
Control Unit Outputs S0 - S3
71
Control Unit Outputs R0 & R1
72
Relays Expansion Board 4581 Output 0 - Output 7
72
Inputs and Outputs Expansion Board 4583 Output 0 & Output
72
The 3361 Unit's Outputs Re0 & Re1
72
The 3364 Unit's VO0 - VO2
73
The 3377 Unit's Output (Siren)
73
The 3379 Unit's Output (Sounder)
73
The 4380 Unit's Output (Beacon)
73
13 Output Programming
74
Type of Output
74
Logic
75
Supervised / Not Supervised
75
Output Signal Period
75
Control Expression
78
Trigger Conditions
78
Logical Operators
82
Control Expression Examples
82
14 Interlocking Function
86
Programming of Interlocking Function
86
Interlocking Output
86
Interlocking Input
86
Interlocking Combination
86
Interlocking Indications
88
Information of Interlocking Combinations (H9)
88
Display Interlocking Information (H9/C1)
88
Activate Interlocking Output (H9/C2)
89
Reset Interlocking Output (H9/C3)
89
Disable Interlocking Output (H9/C4)
89
Re-Enable Interlocking Output (H9/C5)
89
Interlocking Control Expressions
89
15 Fire Door Closing
90
16 Functions / Services / Features
91
Sensor Value
91
Week Average Sensor Value
91
Decision Value
92
Alarm Algorithms for Smoke Detectors / Detection Levels / Offsets
92
Alarm Algorithm / Alternative Alarm Algorithm
93
Filtering Algorithm
94
Smouldering Smoke Algorithm
96
Performance Factor
97
Algorithms for Analog Heat Detectors
98
Class A1 Algorithm
99
Class A2 S Algorithm
99
Self Verification
99
Class B S Algorithm
99
Minimum / Maximum Sensor Values
100
2-Zone / 2-Address Dependence (Co-Incidence Alarm)
101
2-Zone Dependence
101
2-Address (-Unit) Dependence
102
Reset of 2-Zone / 2-Address Dependence
102
Delayed Alarm
103
Alert Annunciation
104
Alarm Acknowledgement Facility (AAF)
106
Quiet Alarm
108
Fire Alarm Type a and Fire Alarm Type B
108
Fire Alarm Type B
109
Fire Alarm Type a
109
Disable Alarm Points and Outputs
109
Disable Zone
110
Disable Zone / Address
110
Disable Control Output
110
Disable / Re-Enable Output Type
110
Disable Interlocking Output
110
Disable / Re-Enable Alarm Devices
110
Disable Outputs for Routing Equipment
110
Disconnect & Re-Connect Loop / Zone Line Input
111
External Time Channels 15-63
111
Test Mode
111
Test Alarm Devices
111
Test of Routing Equipment
112
Calibration of Supervised Outputs
112
Service Signal
112
Fault Signal (Fault Condition)
113
Alarm Texts
113
Creating the Alarm Texts Via Wing3
113
Downloading Alarm Texts to the Du:s 1728 / 1735 / 1736 and Ext. Fbp:s 1826 / 1828
115
Real Time Clock (RTC)
115
Daylight Saving Time
116
Loss of Main Power Source
116
Evacuate
116
Wing3 Menu Tools
117
17 Special New Zealand Functions
119
Alarm Devices
119
Silence Alarm Devices (Inside Switch)
119
New Zealand FB Silence Switch (Outside Switch)
119
Battery Faults
121
FAULT: Battery
121
FAULT: Low Battery Capacity
121
Watchdog Reset
121
Routing Equipment Isolate (Disable)
121
Acknowledged Alarm
121
18 Cyber Sensor Functions
123
Pulse up - down Counter
124
Pulse up - down Counter for Smoke
124
Pulse up - down Counter for Temperature
124
Fire Judgement
124
Pulse up - down Counter for Smoke & Temperature
124
Alarm Threshold Levels
125
Learning Function / Learning Conditions
125
Learning Conditions
125
Alarm Delay Time
127
Analog Data Output
128
Sensitivity Compensation
128
Self Diagnosis of Internal Devices
129
Address Setting Check
129
19 Control Unit Properties
130
Control Unit Properties Dialog Box
130
General Information
130
Peripherals
130
Misc
130
Wing3 Control Unit Pop-Up Menu
131
Reset Alarm Counter
131
Software Version
131
Upgrade Number of Alarm Points
131
Restart
132
Delete
132
Properties
132
20 System Properties (Settings)
133
System Properties Dialog Box
133
Name
133
User Definable Text
133
System Properties, Page 1
133
System Properties, Page 2
135
Menu System
136
Properties
136
Time Channels
136
Alarm Algorithms
138
Output Signal Periods
140
National Holidays
141
Two Zone Dependence
142
Statistics (System Information)
143
Edit Alarm Texts
143
21 Compatibility
144
22 Cable Types
145
TLON Network Cables
145
COM Loop Cables
145
Ext. FBP / Display Units Cables
145
Conventional Zone Line Cables
145
Alarm Device Cables
146
Other Cables
146
23 COM Loop Cable Length
147
24 Current Consumption
150
25 Power Supply
154
Charger Functions
155
Charging
155
Battery Charging Functions
155
Security Functions
155
Current Consumption Calculations
156
Rectifier (Main Power Source)
157
Battery (Second Power Source)
157
Fuses
158
Form / Table of Current Consumption
158
26 W Versions
160
27 Technical Data
161
28 Limitations
162
User Definable Texts
162
C.I.e. / System
162
29 National Regulations
164
30 Drawings / Connection Diagrams
165
31 Revision History
166
Related Products
Panasonic MEW01091
Panasonic MEW01349
Panasonic MEW01777
Panasonic MEWNET-F
Panasonic MEDHT4430NL1
Panasonic MEDL*83 Series
Panasonic MEDLN83SE
Panasonic MEDDT7364P
Panasonic MEDLN83BL
Panasonic MEDLT93BM
Panasonic Categories
Air Conditioner
Camcorder
TV
Digital Camera
Cordless Telephone
More Panasonic Manuals