beautypg.com
Manuals
Brands
Siemens Manuals
Smoke Alarm
FCI2017-U1
Siemens FCI2017-U1 Manuals
Manuals and User Guides for Siemens FCI2017-U1. We have
1
Siemens FCI2017-U1 manual available for free PDF download: Mounting & Installation
Siemens FCI2017-U1 Mounting & Installation (46 pages)
Periphery board (250p) / Periphery board (500p)
Brand:
Siemens
| Category:
Smoke Alarm
| Size: 1.38 MB
Table of Contents
Table of Contents
3
1 Periphery Board (250P) FCI2016
5
Description
5
Installation
7
Views
8
Configuration Input Power and Battery
10
Wiring Power Supply Input and Battery
10
X301 Power Supply Terminal Block 1
11
X302 Power Supply 2 Terminal Block
12
X305 Jumper - Power Supply 2 On/Off
12
X304 Voice Supply +24 V
13
X303 Battery Terminal
13
NAC Circuits
13
Wiring the NAC Circuits
14
X601 Terminal Block - NAC 1 Class a / NAC 1-1 Class B / NAC 1-2 Class B
14
X602 Jumper - ENABLE/DISABLE DEGRADED MODE for NAC 1 Class a or NAC 1-1 Class B
15
X603 Jumper - ENABLE/DISABLE DEGRADED MODE for NAC 1-2 Class B
15
X604, X605, X606 Jumper - NAC 1 Class A/B
15
X403 Jumper - DEGRADE ALARM SILENCEABLE
16
Bell Follower Input
16
Wiring
16
X801 Bell Follower Terminal Block
16
Auxiliary DC 24 V Output
17
Wiring
17
X1001 Auxiliary Output Terminal Block
17
Relays
17
Wiring
18
X1101 Relay Terminal Block
18
Detector Circuits, Circuit Driver 1 (Circuits 1 and 2)
18
Wiring
19
X1401 Terminal Block - Detector Circuit 1
20
X1402 Terminal Block - Detector Circuit 2
20
Indicators
20
Reset Buttons
20
S100 RESET Periphery Board
20
Technical Data
21
2 Periphery Board (500P) FCI2017
25
Description
25
Installation
27
Views
28
Configuration Input Power and Battery
30
Wiring Power Supply Input and Battery
30
X301 Power Supply Terminal Block 1
31
X302 Power Supply 2 Terminal Block
32
X305 Jumper - Power Supply 2 On/Off
32
X304 Voice Supply +24 V
32
X303 Battery Terminal
33
NAC Circuits
33
Wiring the NAC Circuits
34
NAC 1-2 Class B
35
X602 Jumper - ENABLE/DISABLE DEGRADED MODE for NAC 1 Class a or NAC 1-1 Class B
35
X603 Jumper - ENABLE/DISABLE DEGRADED MODE for NAC 1-2 Class B
35
X604, X605, X606 Jumper - NAC 1 Class A/B
35
X403 Jumper - DEGRADE ALARM SILENCEABLE
36
Bell Follower Input
36
Wiring
36
X801 Bell Follower Terminal Block
36
Auxiliary DC 24 V Output
37
Wiring
37
X1001 Auxiliary Output Terminal Block
37
Relays
37
Wiring
38
X1101 Relay Terminal Block
38
Detector Circuits, Circuit Driver 1 (Circuits 1 and 2) and Circuit Driver 2 (Circuits 3 and 4)
38
Wiring
39
X1401 and X1801 Terminal Block - Detector Circuits 1 and 3
40
X1402 and X1802 Terminal Block - Detector Circuits 2 and 4
40
Indicators
41
Reset Buttons
41
S100 RESET Periphery Board
41
Technical Data
42
3 FCC Statement
45
Related Products
Siemens FCI2016-U1
Siemens FDOOT241-A5
Siemens FDA241
Siemens FDA221
Siemens FDBZ292
Siemens FDA2 1 Series
Siemens FDA2 Series
Siemens FDA261
Siemens FDA262
Siemens FDAZ292
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals