beautypg.com
Manuals
Brands
Siemens Manuals
Media Converter
SINAMICS G120C PN
Siemens SINAMICS G120C PN Manuals
Manuals and User Guides for Siemens SINAMICS G120C PN. We have
2
Siemens SINAMICS G120C PN manuals available for free PDF download: Operating Instructions Manual
Siemens SINAMICS G120C PN Operating Instructions Manual (470 pages)
SINAMICS G120C series Low voltage converter Built-in units with frame sizes AA - F
Brand:
Siemens
| Category:
Media Converter
| Size: 12.31 MB
Table of Contents
Description
3
Changes in the Current Manual
5
Table of Contents
7
1 Fundamental Safety Instructions
15
General Safety Instructions
15
Equipment Damage Due to Electric Fields or Electrostatic Discharge
20
Warranty and Liability for Application Examples
21
Industrial Security
22
Residual Risks of Power Drive Systems
23
2 Introduction
25
About the Manual
25
Guide through the Manual
26
Saving Settings and Series Commissioning
26
3 Description
29
Scope of Delivery Inverters FSAA
30
Scope of Delivery Inverters FSD
32
Directives and Standards
34
Optional Components
36
Motors and Multi-Motor Drives that Can be Operated
40
4 Installing
41
EMC-Compliant Setup of the Machine or Plant
41
Control Cabinet
42
Cables
43
Electromechanical Components
46
Mounting Base Components
47
Installing the Inverter
50
Mounting the Line Reactor
57
Mounting the Output Reactor
59
Mount Du/Dt Filter Plus Voltage Peak Limiter
62
Mounting the Braking Resistor
63
Connect the Line Supply, Motor and Braking Resistor
65
Permissible Line Supplies
65
TN Line System ((400-V-Umrichter))
65
TT Line System
66
IT System
67
Protective Conductor
67
Connecting the Inverter and Inverter Components to the Supply
69
Branch Circuit Protection
75
Maximum Permissible Motor Cable Length
77
Connecting the Motor to the Inverter in a Star or Delta Connection
79
Operating a Converter on the Residual Current Device
80
Connecting the Interfaces for the Inverter Control
81
Overview of the Interfaces
81
Fieldbus Interface Assignment
83
Terminal Strips
84
Factory Setting of the Interfaces
88
Default Setting of the Interfaces
91
Fail-Safe Digital Input
100
Wiring Terminal Strips
101
Connecting the Cable Shields (FSAA
103
Connecting Cable Shields (FSD
104
Fieldbus Interfaces
104
Connecting the Inverter to PROFINET
104
Communication Via PROFINET IO and Ethernet
104
Connecting the PROFINET Cable to the Inverter
106
What Do You Have to Set for Communication Via PROFINET
106
Installing GSDML
107
Connecting the Inverter to PROFIBUS
108
Connecting the PROFIBUS Cable to the Inverter
108
What Do You Have to Set for Communication Via PROFIBUS
109
Installing the GSD
110
Setting the Address
110
Connecting a Motor Holding Brake
112
Monitoring the Temperature of the Braking Resistor
113
5 Commissioning
115
Commissioning Guidelines
115
Tools to Commission the Inverter
116
Preparing for Commissioning
117
Collecting Motor Data
117
Inverter Factory Setting
118
Minimum and Maximum Speed
119
Quick Commissioning Using the BOP-2 Operator Panel
120
Overview of Quick Commissioning
121
Start Quick Commissioning and Select the Application Class
122
Standard Drive Control
124
Dynamic Drive Control
126
Expert
128
Identifying the Motor Data and Optimizing the Closed-Loop Control
133
Quick Commissioning with a PC
135
Creating a Project
135
Transfer Inverters Connected Via USB into the Project
136
Go Online and Start Quick Commissioning
139
Overview of Quick Commissioning
140
Select the Application Class
141
Standard Drive Control
143
Dynamic Drive Control
144
Expert
145
Identify Motor Data
148
Restoring the Factory Setting
151
Resetting the Safety Functions to the Factory Setting
152
Restore the Factory Settings (Without Safety Functions)
155
6 Advanced Commissioning
157
Overview of the Inverter Functions
157
Sequence Control When Switching the Motor on and off
160
Adapt the Default Setting of the Terminal Strip
162
Digital Inputs
163
Digital Outputs
165
Analog Input
166
Analog Output
170
Controlling Clockwise and Counter-Clockwise Operation Via Digital Inputs
173
Two-Wire Control, Method 1
174
Two-Wire Control, Method 2
175
Two-Wire Control, Method 3
176
Three-Wire Control, Method 1
177
Three-Wire Control, Method 2
178
Drive Control Via PROFIBUS or PROFINET
179
Receive Data and Send Data
179
Telegrams
180
Control and Status Word 1
182
NAMUR Message Word
185
Parameter Channel
186
Examples for Using the Parameter Channel
189
Extend Telegrams and Change Signal Interconnection
191
Slave-To-Slave Communication
193
Acyclically Reading and Writing Inverter Parameters
193
Drive Control Via Modbus RTU
194
Drive Control Via USS
197
Drive Control Via Ethernet/Ip
200
Jogging
201
Limit Position Control
202
Switching over the Drive Control (Command Data Set)
204
Motor Holding Brake
206
Free Function Blocks
210
Selecting Physical Units
211
Select the Motor Standard
211
Selecting the System of Units
211
Selecting the Technological Unit of the Technology Controller
213
Setting the Motor Standard, System of Units and Technology Unit Using STARTER
213
Safe Torque off (STO) Safety Function
215
Function Description
215
Commissioning STO
217
Safety Functions Password
217
Configuring a Safety Function
219
Interconnecting the "STO Active" Signal
221
Setting the Filter for Fail-Safe Digital Inputs
223
Setting the Forced Checking Procedure (Test Stop)
225
Activating the Settings and Checking the Digital Inputs
228
Acceptance - Completion of Commissioning
232
Setpoints
235
Overview
235
Analog Input as Setpoint Source
236
Specifying the Setpoint Via the Fieldbus
237
Motorized Potentiometer as Setpoint Source
238
Fixed Speed Setpoint as Setpoint Source
240
Setpoint Calculation
243
Overview of Setpoint Processing
243
Invert Setpoint
244
Inhibit Direction of Rotation
245
Skip Frequency Bands and Minimum Speed
246
Speed Limitation
247
Ramp-Function Generator
248
PID Technology Controller
252
Motor Control
258
Reactor, Filter and Cable Resistance at the Inverter Output
258
V/F Control
259
Characteristics of U/F Control
261
Optimizing Motor Starting
264
Encoderless Vector Control
268
Structure of Vector Control Without Encoder (Sensorless)
268
Optimizing the Speed Controller
270
Advanced Settings
273
Friction Characteristic
274
Moment of Inertia Estimator
276
Application Examples for Closed-Loop Motor Control
282
Electrically Braking the Motor
283
DC Braking
285
Compound Braking
288
Dynamic Braking
290
Overcurrent Protection
292
Inverter Protection Using Temperature Monitoring
293
Motor Protection with Temperature Sensor
296
Motor Protection by Calculating the Temperature
299
Motor and Inverter Protection by Limiting the Voltage
301
Flying Restart - Switching on While the Motor Is Running
303
Automatic Restart
305
Kinetic Buffering (VDC Min Control)
309
Efficiency Optimization
311
Line Contactor Control
314
Calculating the Energy Saving for Fluid Flow Machines
316
Switchover between Different Settings
318
7 Saving Settings and Series Commissioning
321
Saving Settings on a Memory Card
322
Memory Cards
322
Saving Setting on Memory Card
323
Transferring the Setting from the Memory Card
327
Safely Remove the Memory Card
330
Activate Message for a Memory Card that Is Not Inserted
332
Saving the Settings to a PC
333
Saving Settings to an Operator Panel
337
Other Ways to Back up Settings
339
Write Protection
340
Know-How Protection
342
Extending the Exception List for Know-How Protection
345
Activating and Deactivating Know-How Protection
346
8 Alarms, Faults and System Messages
349
Operating States Indicated on Leds
350
Identification & Maintenance Data (I&M)
353
Alarms, Alarm Buffer, and Alarm History
354
Faults, Alarm Buffer and Alarm History
357
List of Alarms and Faults
361
9 Corrective Maintenance
369
Spare Parts Compatibility
369
Replacing Inverter Components
370
Overview of How to Replace an Inverter
371
Replacing a Converter with Enabled Safety Function
373
Replacing a Converter Without Enabled Safety Function
378
Replacing a Converter Without Data Backup
380
Replacing Devices with Active Know-How Protection
380
Spare Parts
383
Replace the Fan Unit for the Heat Sink
385
Replacing the Roof-Mounted Fan
389
Firmware Upgrade and Downgrade
391
Upgrading the Firmware
393
Firmware Downgrade
395
Correcting an Unsuccessful Firmware Upgrade or Downgrade
397
Reduced Acceptance after Component Replacement and Firmware Change
398
If the Converter no Longer Responds
399
10 Technical Data
401
Technical Data of Inputs and Outputs
401
High Overload and Low Overload
403
Overload Capability of the Inverter
404
General Inverter Technical Data
405
Technical Data Dependent on the Power
406
Data Regarding the Power Loss in Partial Load Operation
412
Current Reduction Depending on Pulse Frequency
413
Restrictions for Special Ambient Conditions
414
Electromagnetic Compatibility of the Inverter
418
Harmonic Currents
421
EMC Limit Values in South Korea
421
Accessories
422
Line Reactor
422
Line Filter
423
Output Reactor
424
Sine-Wave Filter
425
Du/Dt Filter Plus Voltage Peak Limiter
426
Braking Resistor
427
Appendix
429
New and Extended Functions
429
Firmware Version 4.7 SP9
429
A.1 New and Extended Functions
429
Firmware Version 4.7 SP6
431
Firmware Version 4.7 SP3
432
Firmware Version 4.7
435
A.1.4 Firmware Version 4.7
435
Firmware Version 4.6 SP6
436
Firmware Version 4.6
437
A.1.6 Firmware Version 4.6
437
Firmware Version 4.5
438
A.1.7 Firmware Version 4.5
438
Handling the BOP 2 Operator Panel
439
Menu Structure, Symbols and Keys
439
Changing Settings Using BOP-2
440
Changing Indexed Parameters
441
Directly Entering the Parameter Number and Value
442
A Parameter Cannot be Changed
443
The Device Trace in STARTER
444
Interconnecting Signals in the Converter
447
Fundamentals
447
Application Example
449
A.4.2 Application Example
449
Connecting a Fail-Safe Digital Input
451
Acceptance Test for the Safety Function
453
Recommended Acceptance Test
453
Machine Documentation
456
A.6.2 Machine Documentation
456
Documenting the Settings for the Basic Functions, Firmware V4.4
458
Manuals and Technical Support
459
Overview of the Manuals
459
Configuring Support
461
A.7.2 Configuring Support
461
Product Support
462
A.7.3 Product Support
462
Index
463
Siemens SINAMICS G120C PN Operating Instructions Manual (478 pages)
Low voltage converters
Brand:
Siemens
| Category:
Inverter
| Size: 18.83 MB
Related Products
Siemens SINAMICS G12
Siemens SINAMICS G120C DP
Siemens SINAMICS G120XA
Siemens SINAMICS G120X
Siemens SINAMICS G120 PM240P-2
Siemens SINAMICS G110D 6SL3511-0PE17-5AM0
Siemens SINAMICS G110D 6SL3511-0PE21-5AM0
Siemens SINAMICS G110D 6SL3511-0PE25-5AM0
Siemens SINAMICS G110D 6SL3511-0PE24-0AM0
Siemens SINAMICS G110D 6SL3511-0PE23-0AM0
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals