WAGNER TITANUS PRO-SENS 2 manual available for free PDF download: Technical Manual
WAGNER TITANUS PRO-SENS 2 Technical Manual (224 pages)
Air sampling smoke detection system
Brand:
WAGNER
| Category:
Smoke Alarm
| Size: 6.24 MB
Table of Contents
Table of Contents
5
1 General
11
Introduction
11
Safety Information
11
Guarantee
12
Copyright
12
Packaging
12
Disposal
13
2 Product Description
15
Features of the TITANUS PRO·SENS
15
Areas of Application
17
3 Technical Description
21
System Description
21
Function
22
TITANUS PRO·SENS ® and Accessories
25
Overview
25
Diagnostics
28
Response Indicators
29
Device Support
30
Pipe System
31
Overview of Available Pipe Components
31
Air Sampling Points for Room Monitoring
33
Aspiration-Reducing Film Sheets
33
Air Flow Reducer Clips
34
Ceiling Feed-Through for Hidden Installations
35
Air Filter for Dusty Areas
37
Air Return for Pressurised and Dusty Areas
40
Noise Suppressor
41
Steam Trap for Humid Areas
42
Detonation Prevention Device for Endangered Areas
44
4 Technical Data
47
Titanus Pro·sens
47
Pipe System - TITANUS PRO·SENS
50
5 Design
51
General
51
Regulations
52
Pipe System
53
Air Flow Monitoring
59
Sensitivity
60
Project Planning Limits
61
Pipe Design
63
Project Planning Guidelines
63
Pipe Accessories
64
Sensitivity and Pipeline Project Design
65
Pipeline Project Planning with Pipe Accessories
65
Aperture Diameter
69
Special Project Design
73
Project Planning for Individual Aperture Monitoring
73
I - Pipe System
73
U - Pipe System
75
M - Pipe System
77
Double U - Pipe System
79
Simplified Pipe Project Design
81
I - Pipe System
81
U - Pipe System
82
M - Pipe System
83
Double - U - Pipe System
84
Project Planning with Branch Pipes
86
Project Planning with Long Intake Lines > Ø 25 MM
88
Project Planning with Acceleration Apertures
90
Project Design for Forced Air Flow
95
Project Design with Air Sampling Hose
99
Project Planning with Air Return
100
Mains Supply
102
6 Installation
105
General
105
Opening the TITANUS PRO·SENS
106
Settings
107
Detector Module
107
Setting of the Response Sensitivity
107
Delay Period of the Alarm Activation
107
Activating Threshold of the Air Flow Monitoring
108
Delay Period of the Air Flow Fault
108
Fault Display
109
Logic·sens
109
Function of the Collective Fault Contact
109
Setting of the Fan Voltage TITANUS PRO·SENS
110
Connect the Fan at TITANUS PRO·SENS
111
Setting of Fan Voltage at TITANUS PRO·SENS ® -SL
112
Connecting the Fan at TITANUS PRO·SENS ® -SL
113
Installation of the Reset Board
114
Mounting Location
117
Connection of the Air Sampling Pipe
120
Electrical Connection
121
Connection to FAS, with Reset Button
122
With Reset Button
124
Connection to FAS, with Reset Board
125
Installation of the Second Detector Module
127
Response Indicator - Electrical Connection
129
Data Log
130
7 Installation Pipe System
131
Installation General
131
Installation Pipe System
132
Installation Air Sampling Hose
133
Linear Expansion of the Pipe System
135
Patented Aspiration Apertures
137
Ceilings Feed-Through
139
Ceilings Feed-Through for False Ceiling
139
Other Ceilings Feed-Through
140
Monitoring in Forced Air Flow Systems (Ventilation or Climatic Applications)
142
Detection at Air Inlets/Outlets
142
Detection in Bypass Systems
142
Filter
144
Installation of the Air Filter Type LF-AD-X
144
Mounting of the Special Filter Type SF-400/650
145
Air Return
147
Noise Suppressor
148
3-Way Ball Valve
150
Steam Traps
152
Steam Trap Type KA
152
Steam Trap Type
153
Detonation Prevention Device
154
Test Adapter
156
8 Commissioning
157
Adjustment Air Flow Sensor
158
Adjustment Independent of the Air Pressure
159
Adjustment Dependent on the Air Pressure
160
Detector Module and Alarm Transmission
162
Check Air Flow Monitoring
163
Check Fault Signal Transmission
165
Operational Check of TITANUS PRO·SENS
166
Preparations for Operational Check
166
Operational Check
167
9 Maintenance
171
Visual Check
171
Flash Code Table
171
Check Detector Module and Alarm Transmission
172
Check Pipe System
172
Exchange of Detector Module
173
Changing the Air Filter LF-AD-X
175
Changing Special Air Filter
177
Related Products
WAGNER TITANUS PRO-SENS 2SL
WAGNER TITANUS PRO-SENS
WAGNER TITANUS PRO-SENS SL
WAGNER Stati-Kit 2000 0292003
WAGNER GM 2600 0179070
WAGNER Super Finish 27
WAGNER Spraypack 22-18S AC
WAGNER Finish 230 Ac Compact
WAGNER ProSpray 24
Wagner Super Finish 23
WAGNER Categories
Paint Sprayer
Lantern
Power Tool
Water Pump
Measuring Instruments
More WAGNER Manuals