761-214
WAGO 761-214 Manuals
Manuals and User Guides for WAGO 761-214. We have
1
WAGO 761-214 manual available for free PDF download: Manual
WAGO 761-214 Manual (102 pages)
Telecontrol Module Compact, 8 AI, ESP, DSP For WAGO-TO-PASS 761. Telecontrol module for fault detection/indication, monitoring and remote control.
Brand:
WAGO
| Category:
Control Unit
| Size: 3.05 MB
Table of Contents
Table of Contents
3
Table of Contents
5
Notes about this Documentation
6
Validity of this Documentation
6
Copyright
6
Symbols
7
Number Notation
9
Font Conventions
9
Table 1: Number Notation
9
Table 2: Font Conventions
9
Important Notes
10
Legal Bases
10
Subject to Changes
10
Personnel Qualification
10
Use of the TO-PASS Telecontrol Modules in Compliance with Underlying Provisions
10
Technical Condition of Specified Devices
10
Disclaimer
11
Firmware Licensing Terms
11
Firmware with Open Source GPL
11
Block Rounding for GPRS Connections
11
Safety Advice (Precautions)
12
Device Description
15
Scope of Delivery
15
Use
15
Table 3: Overview of Functions
16
View
17
Figure 1: Front View
17
Connectors
18
Antenna
18
Figure 2: Antenna Connection
18
Operating Voltage
19
Figure 3: Terminal Assignment for Operating Voltage
19
Table 4: Terminal Assignment for Operating Voltage
19
Grounding
20
Framework Assembly
20
Insulated Assembly
20
Grounding of the TO-PASS
20
Telecontrol Module
20
Table 5: WAGO Ground Wire Terminals
20
Shielding
21
General
21
Bus Lines
21
Signal Lines
21
WAGO Shield Connecting System
22
Figure 4: Example of the WAGO Shield Connecting System
22
Digital Inputs
23
Figure 5: Terminal Assignment for Digital Inputs
23
Table 6: Terminal Assignment for Digital Inputs
23
Counter Inputs
24
Figure 6: Counter Input Pin Assignments
24
Table 7: Counter Input Pin Assignments
24
Analog Inputs
25
Figure 7: Terminal Assignment for Analog Inputs
25
Table 8: Terminal Assignment for Analog Inputs
25
Digital Outputs
27
Figure 8: Terminal Assignment for Digital Outputs
27
Table 9: Terminal Assignment for Digital Outputs
27
Analog Outputs
28
Figure 9: Terminal Assignment for Analog Outputs
28
Table 10: Terminal Assignment for Analog Outputs
28
Serial Interface to PC
29
Figure 10: Serial Interface to the PC and MODBUS Interface
29
Table 11: Serial Interface to the PC
29
Table 12: PC Interface Cable Assignment
29
Display Elements
30
Figure 11: Display Elements
30
Table 13: Display Elements
30
Technical Data
31
Housing
31
Supply
31
GSM Antenna Connection
31
Table 14: Technical Data Housing
31
Table 15: Technical Data Supply
31
Table 16: Technical Data GSM Antenna Connection
31
GSM Communication
32
Digital Inputs
32
Counter Inputs
32
Analog Inputs
32
Table 17: Technical Data GSM Communication
32
Table 18: Technical Data Digital Inputs
32
Table 19: Technical Data Counter Inputs
32
Table 20: Technical Data Analog Inputs
32
Digital Outputs
33
Analog Outputs
33
Data and Event Logger
33
Table 21: Technical Data Digital Outputs
33
Table 22: Technical Data Analog Outputs
33
Table 23: Technical Data Data and Event Logger
33
Approvals
34
Standards and Guidelines
34
Mounting
35
Mounting the TO-PASS ® Telecontrol Module to the DIN Rail
35
Figure 12: Mounting the TO-PASS ® Telecontrol Module to the DIN Rail
35
Removing the TO-PASS ® Telecontrol Module from the DIN Rail
36
Figure 13: Removing the TO-PASS ® Telecontrol Module from the DIN Rail
36
Connect Devices
37
Connecting the Push-Wire Connections to the Conductor
37
Connection Examples
38
Digital Inputs
38
Figure 14: Connection Example for Switch at Input DI1
38
Counter Inputs
39
Figure 15: Connecting Example, Switching Contact at Counter Input DI1
39
Analog Inputs
40
Current Measurement
40
Figure 16: Connection Example of Transducer with Current Output at Input AI1
40
Voltage Measurement
41
Figure 17: Connection Example for Voltage Measurement Via U/I Converter at
41
Digital Outputs
42
Figure 18: Connection Example for a Relay at DO1 Output
42
Analog Outputs
43
Current Measurement
43
Figure 19: Connection Example for a Display Device at AO1 Output
43
Voltage Measurement
44
Commissioning
45
Installing the Operating Software
45
Starting the TO-PASS Telecontrol Module
46
Parameterizing
48
General Settings
48
Figure 20: General Settings
48
Table 24: General Settings
48
Reading Parameters from the Module
50
Identity
51
Figure 21: Configuring the Identity
51
Table 25: Configuring the Identity
52
Addresses
53
Figure 22: Configuring the Addresses
53
Table 26: Configuring the Addresses
54
Configuring Inputs and Outputs
56
Digital Inputs
56
Figure 23: Configuring Digital Inputs 1
56
Figure 24: Configuring Digital Inputs 5
57
Table 27: Configuring of Digital Inputs
57
Multiplex Input
60
Multiplex Settings
61
Figure 25: Configuring Multiplex Operation Settings
61
Table 28: Configuring Multiplex Operation Settings
61
Multiplex Alarm Text
62
Figure 26: Configuring Multiplex Operation Alarm Texts
62
Table 29: Configuring Multiplex Operation Alarm Texts
62
Analog Inputs
63
Figure 27: Configuring the Analog Inputs
63
Table 30: Configuring the Analog Inputs
63
Digital Outputs
65
Figure 28: Configuring the Digital Outputs
65
Table 31: Configuring the Digital Outputs
65
Analog Outputs
66
Figure 29: Configuring the Analog Outputs
66
Table 32: Configuring the Analog Outputs
66
Configuring Error Detectors
68
Alarm Messages for Digital Inputs
68
Limit Messages for Counter Inputs
68
Limit Messages for Analog Inputs
68
Acknowledgement
70
Figure 30: : Configuring the Acknowledgment Response
70
Table 33: Configuring the Acknowledgement Response
70
Transmission Repeat Times
71
Figure 31: Configuring the Transmission Repeat Times
71
Table 34: Configuring the Transmission Repeat Times
72
Time Adjustment
74
Figure 32: Setting the Time Adjustment
74
Table 35: Setting the Time Adjustment
74
Data Logger
75
Figure 33: Configuring the Data Logger
75
Table 36: Configuring the Data Logger
75
Writing Parameters to the Module
76
Operation
77
Remote Query of Process Values
77
Remote Polling Via SMS
78
Table 37: SMS Format
78
Table 38: Items Added to SMS for Counter Inputs
78
Table 39: Counter Status
79
Remote Polling Using the TO-PASS
80
Operating Program
80
Inputs/Outputs
81
Figure 34: Visualization of the Process Values
81
Counters
82
Figure 35: Counter Process Values
82
Telecontrol
83
Telecontrol Via SMS
84
Setting or Resetting a Digital Output
84
Table 40: Example of Parameters for Set DO
84
Setting an Analog Output
85
Table 41: Example of Parameters for Set AO1
85
Changing the Counter Value or Status
86
Table 42: Control Commands for Counters
86
Telecontrol with the TO-PASS
87
Operator Program
87
Inputs/Outputs
88
Figure 36: Visualization of the Process Values
88
Counters
89
Figure 37: Counter Process Values
89
Acknowledging Error Messages
90
Switching to Standby
91
Displaying the Data Logger (DSP)
92
Table 43: Navigation DSP
92
Displaying the Event Logger (ESP)
94
Diagnostics
95
Test Inputs and Outputs
95
Figure 38: Test Inputs and Outputs
95
Testing the Counter Inputs
96
Figure 39: Testing Counters
96
Testing the Connection
97
Figure 40: Testing the Connection
97
Testing the Modem
98
Figure 41: Testing the Modem
98
List of Figures
99
List of Tables
100
Related Products
WAGO 761-216
WAGO 761-217
WAGO 761-210
WAGO 761-113
WAGO WAGO-TO-PASS 761
WAGO 761-111
WAGO 761-316
WAGO 761-110
WAGO 761-314
WAGO 761-114
WAGO Categories
I/O Systems
Control Unit
Power Supply
Switch
Controller
More WAGO Manuals