beautypg.com
Manuals
Brands
YOKOGAWA Manuals
Data Loggers
XL100
YOKOGAWA XL100 Manuals
Manuals and User Guides for YOKOGAWA XL100. We have
3
YOKOGAWA XL100 manuals available for free PDF download: User Manual
YOKOGAWA XL100 User Manual (208 pages)
Portable Data Station, Portable Data Logger
Brand:
YOKOGAWA
| Category:
Data Loggers
| Size: 4.98 MB
Table of Contents
Checking the Contents of the Package
3
Safety Precautions
5
Language Setting at Startup
7
Table of Contents
8
Chapter 1 Explanation of Functions
11
Overview of the XL100
11
Functions of the Input Section
12
Display Function
15
Alarm Function
19
Data Save/Load Function and File Operation Function
25
Setup Function
26
Communication Function (Supported Only on the XL121, XL122, and XL124)
27
Other Main Functions
29
Chapter 2 Part Names and Functions
30
Front Panel and Terminal Block Unit
30
Side Panel and Rear Panel
32
Data Display
33
Setup Display
48
Chapter 3 Handling Precautions and Wiring
54
Wiring the Input Signal Cable
54
Wiring the External I/O Signal Cables
58
Connecting the Power Supply
60
Handling of the Lithium Ion Battery (Sold Separately)
61
Connecting Communication Cables (Supported Only on the XL121, XL122, and XL124)
62
Connecting the USB Memory
66
Chapter 4 Basic Operation
67
Turning ON/OFF the Power Switch
67
Basic Key Operations
70
Setting the Date and Time
82
Resetting the System (Initializing the Settings)
84
Setting the Display Backlight
85
Locking the Keys
86
Inserting and Removing the External Storage Media
87
Chapter 5 Setting the Input Channels
89
Setting the Analog Input Channels
89
Setting the Pulse Input Channel
93
Setting the Logic Input Channel
97
Directly Setting the Range, Span, and Scale Using the RANGE Key
99
Chapter 6 Setting Alarms
100
Setting the Alarm on Analog Input Channels
100
Setting the Alarm on Pulse Input Channels
102
Setting the Alarm on Logic Input Channels
104
Setting Alarms on Calculation and Communication Channels (Communication Channels Are Supported Only on the XL121, XL122, and XL124)
106
Setting Alarm Output and Display
108
Searching Alarms
110
Chapter 7 Setting the Displayed Contents and Operating the Displays
111
Switching the Operation Mode and Display
111
Setting Groups
113
Setting the Background Color, Grid, and Bar Graph Base Position
115
Setting Alarm Lines
117
Switching the Time Scale
119
Chapter 8 Setting the Calculation of Measured Data
120
Setting the Calculation
120
Setting the Statistical Calculation
123
Chapter 9 Setting and Controlling the Data Saving and Loading Operations
125
Setting the Save Operation of Measured and Calculated Data
125
Loading Measurement or Calculation Data Files
132
Manually Saving Measured and Calculated Data
133
Saving the Alarm Summary Data
134
Saving the Log Data
135
Saving and Loading Setup Data
136
Renaming Files
137
Deleting Files
138
Formatting the External Storage Media or Internal Memory
141
Initializing Log Information
142
Automated Measurement and Save Function
143
Chapter 10 Setting the Communication Function
147
Setting the Serial Communication (RS-232, RS-485, Modbus, and Communication Channel)
147
Setting the USB ID
151
Setting the Ethernet Interface
152
Setting the FTP Client
156
Setting the Web Server
158
Setting the E-Mail Transmission
160
Chapter 11 Other Functions
163
Setting the Print Output and Executing the Print Operation (Supported Only on the XL121, XL122, and XL124)
163
Setting the Beep Sound
166
Set the ID Number
167
Setting the Language
168
Setting the Temperature Unit
169
Registering Users
170
Setting and Executing Key Login/Logout and
171
Displaying System Information
173
Setting the Filter
174
Chapter 12 Troubleshooting
175
Troubleshooting
175
Messages and Their Corrective Actions
176
Disposing the Product
180
Chapter 13 Specifications
181
Input Specifications
181
Display Specifications
184
Data Storage Specifications
186
Alarm Specifications
188
General Specifications
192
External Dimensions
194
Appendix
195
Appendix 1 a List of Settings and User Registration Privileges
195
Appendix 2 System Reset and Initialized Items When the Terminal Block Is Changed
202
YOKOGAWA XL100 User Manual (134 pages)
Portable Data Station Communication Function
Brand:
YOKOGAWA
| Category:
Data Loggers
| Size: 0.94 MB
Table of Contents
Safety Precautions
3
Description of Displays and Exemption from Responsibility
4
Table of Contents
5
Chapter 1 Overview of the Communication Functions
7
Relationship between the Communication Function and the Ethernet and Serial Interfaces
7
Explanation of Functions
8
Chapter 2 Ethernet Interface
13
Ethernet Interface Specifications
13
Connecting of the Ethernet Interface
14
Configuring of the Ethernet Interface
15
Checking the Connection Status of the Ethernet Interface
19
Setting the FTP Client (Setting the Auto Transfer of Measurement and Alarm Data Files)
20
FTP Test
23
Setting the Login of Ethernet Communications
25
Showing the Error, Communication, and FTP Log Displays
28
Setting the Web Server Function
31
Showing and Using the Monitor or Operator Page
34
2.11 Setting the E-Mail Transmission Function
36
E-Mail Transmission Test
41
2.13 Starting/Stopping E-Mail Transmissions
43
Chapter 3 Serial Interface
44
Interface Specifications and Setup Procedure
44
USB Communication Specifications and Setup Procedure
51
Chapter 4 Modbus Protocol
53
Modbus Protocol Specifications and Function Codes
53
Register Assignments (for Modbus Slave)
54
Modbus Error Response (for Modbus Slave)
55
Setting the Modbus Master Function
56
Data Dropout Handling of the Modbus Master
59
Chapter 5 Standard Protocol
61
Command Syntax
61
Response Syntax
63
A List of Commands
79
Input Range Parameters
83
Basic Setting Commands
92
Output Commands (Control)
102
Output Commands (Setting/Measurement/Data Output)
103
Output Commands (RS-485 Dedicated Commands)
105
Maintenance/Test Commands (Available When Using the Maintenance/Test Server Function Via Ethernet Communications)
106
Chapter 6 Status
111
Status Information Andfilter
111
Bit Structure of the Status Information
112
Chapter 7 Error Messages
114
Error Messages Related to Settings
114
Error Messages Related to Operation
116
Communication Error Messages
121
Appendix 1 ASCII Character Codes
123
Appendix 2 Login Process
124
Appendix 3 Data Output Flow
126
Appendix 4 Time Zones and XG Command Parameters
128
YOKOGAWA XL100 User Manual (51 pages)
Portable Data Logger/Portable Data Station
Brand:
YOKOGAWA
| Category:
Data Loggers
| Size: 2.18 MB
Table of Contents
Introduction
2
Safety Precautions
3
Table of Contents
4
1 Checking the Contents of the Package
5
2 Flow of Operation
6
3 Names and Functions of Parts
7
4 How to View the Display
10
5 Introduction of the Main Functions
16
Input Type and Calculation
16
Alarm Function
17
Saving Data
18
Triggers
19
File Operations
19
Communication Function
20
6 Operation Mode and Basic Key Operations
22
Operation Modes and Switching the Operation Mode
22
Switching the Display in Free Running Mode or Logging Mode
23
Switching the Menu in Setting Mode
23
Key Operations for Entering Characters
24
Key Operations for Entering Values
24
7 Signal Wiring
25
8 Connecting to the Power Supply and Turning the Power Switch ON/OFF
27
Connecting the Power Supply
27
Turning the Power Switch ON/OFF
28
9 Setting the Input Channel
30
10 Setting the Data Save Operation
34
11 Confirming the Settings and Performing the Measurement
39
12 Inserting an External Storage Medium and Saving Data
40
Inserting an External Storage Medium
40
Starting the Data Save Operation
41
Stopping the Data Save Operation
41
13 Analyzing the Saved Data
42
Loading the Saved Data File
42
Loading the Measured Data
44
Displaying Statistical Calculation Values
44
14 Troubleshooting
45
Index
46
Related Products
YOKOGAWA XL112
YOKOGAWA XL111
YOKOGAWA XL114
YOKOGAWA XL121
YOKOGAWA XL124
YOKOGAWA XL122
YOKOGAWA IM XL100C-E
YOKOGAWA XS550
YOKOGAWA XS110A
YOKOGAWA Sushi Sensor XS530
YOKOGAWA Categories
Measuring Instruments
Test Equipment
Transmitter
Controller
Media Converter
More YOKOGAWA Manuals